Replacing center plate O-ring
1.
Identify the center plate O-ring, lift it from its groove, and discard, Figure 1.
2.
Position and press the new O-ring (size 2-164) into the groove.
Figure 1
Lubricate O-rings with Dow Corning Molykote
®
111 lubricant.
O-ring
Installing gear chamber to center plate and pump chamber
1.
Using Phillips #2 screwdriver, remove the bearing grease port screw shown in Figure 1. This will allow air to vent
from the blind bearing cavity behind the driven shaft seal during installation of the gear chamber.
Continued on next page