Troubleshooting
Error Display In LCD Screen
NOTE:
To clear Error Code, push "ENTER" - If error remains, the code will appear again.
Maintenance
1.
Each month, check that the fluid level is within 1/4" of the fill spout lip while jacks and slide-outs are
fully retracted.
NOTE:
Always fill the reservoir with the jacks and slide-outs in the fully retracted position. Filling reservoir
when jacks and slide-outs are extended will cause reservoir to overflow into its compartment when
jacks and slide-outs are retracted.
2.
Inspect and clean all power unit electrical connections prior to the first use of the unit of the season
and prior to storing the unit. If corrosion is evident, clean all corrosion with a wire brush and apply
dielectric grease to the connections.
3.
Remove dirt and road debris from jacks as needed.
4.
If jacks are down for extended periods, it is recommended to spray exposed leveling jack rods with a
silicone lubricant every three months for protection. If the unit is located in a salty air environment, it is
recommended to spray the rods every 4 to 6 weeks.
Fluid Recommendation
The Lippert Electronic Leveling System is pre-filled, primed and ready to operate direct from the
manufacturer. Type “A” Automatic Transmission Fluid (ATF) is utilized and will work. ATF with Dexron III® or
Mercon 5® or a blend of both is recommended by Lippert Components, Inc.
In colder temperatures (less than 10° F) the jacks may extend and retract slowly due to the fluid’s molecular
nature. For cold weather operation, fluid specially formulated for low temperatures may be desirable. For a
list of approved fluid specifications, see TI-188.
LCD Message
What's Happening?
What Should I Do?
"EXCESS ANGLE"
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the unit.
"BAD CALIBRATION"
Unit zero point was not set correctly. Reset zero point. See "Calibration."
"FEATURE DISABLED"
Front of unit below level when
starting Auto Level process.
Raise front of unit above level and restart
Auto Level process.
"LOW VOLTAGE"
Bad connection or wiring.
Discharged or bad battery.
Check wiring - repair or replace.
Test battery voltage under load - charge or
replace.
"OUT OF STROKE"
Unsecured controller.
Uneven or sloped site.
Check and secure controller placement.
Relocate the unit.
"EXTERNAL SENSOR"
Bad connection or wiring.
Replace or repair connection to rear remote
sensor.
"JACK TIME OUT"
System could not level in expected
time.
Check for obstructions, leaks, fluid level and
voltage to power unit motor under load.
"AUTO LEVEL FAILURE"
Unsecured controller.
Voltage drop.
Check and secure controller placement.
Test battery voltage under load - charge or
replace.