LK2 Service Manual
Page12
Copyright © 2000 Linn Products Limited. All rights reserved.
Contents
Paul O'Neill
Fuse blowing
Constant
Big capacitor(s) faulty –
probably internally short
circuit. Measure across both
capacitors on the channel
that is causing the fuse to
blow – a faulty capacitor will
measure short circuit or
certainly low impedance. If in
doubt, compare with good
channel . See
Introduction
to Fault Finding
section
(accessible via Linfo Website
- Product Information) for tips
on how to isolate faulty board
Replace faulty capacitor
Part details: 10000uF; +/- 20%;
64V; Electrolytic Capacitor (Linn
part no: CAP 085)
Same part can be used for any
version of LK2
Fuse blowing
Constant
Fault inside LK2, e.g. short
circuit or similar.
See
Introduction to Fault
Finding
section (accessible via
Linfo Website - Product
Information) for tips on tracing the
fault. Also see circuit diagrams.