Paul O'Neill

Fuse blowing

Symptom

Circumstances

Possible Cause(s)

Cure

Fuse blowing

May be intermittent

Wrong type of fuse fitted

Replace fuse(s) with correct
value & type.
Fuse in mains lead should be 5A.
Fuse in LK2 should be “Slow
Blow” – look for a ‘T’ before the
rating on the fuse. Correct types
are:
100-115V    -    T3.15A antisurge
220-240V    -    T6.3A antisurge

Fuse blowing

May be intermittent

Mains surges

Consult an electrician or your
electricity supply company..

Doesn’t power up
or
Powers up
(display LED lit)
but no function.

Possible
distortion or poor
sound quality

May be intermittent

Wrong mains voltage for LK2
type – mains voltage is too
high (e.g. 115V unit being
used with 240V mains
supply.)

Check voltage rating on
underside of LK2. If wrong,
transformer will require
replacement. Correct part
numbers are:
MCAS 001/100 for 100V mains
MCAS 001/115 for 115V mains
MCAS 001/220 for  220V mains
MCAS 001/240 for 240V mains
Our stock of these transformers is
very limited, so it may not be
possible to supply the part you
require.

Fuse blowing

May be intermittent
but usually constant

Transformer faulty. To check
if it is definitely the
transformer, power down the
unit, replace fuse, disconnect
the transformer output from
the Main board and power
up. If the transformer IS the
cause, the fuse will continue
to blow. If the fuse remains
intact, the fault is more likely
to be on the board.

Replace transformer. Correct part
numbers are:
MCAS 002/100 for 100V mains
MCAS 002/115 for 115V mains
MCAS 002/220 for  220V mains
MCAS 002/240 for 240V mains
Our stock of these transformers is
very limited, so it may not be
possible to supply the part you
require.

Fuse blowing

Constant

Bridge rectifier diode on
amplifier board faulty
(probably internally short
circuit). These are the four
large diodes which can be
found on the underside of
each amplifier board, under
the big capacitors Try
measuring across all four
with an ohmmeter – if one
has an internal short circuit, it
should be quite obvious.

Replace faulty bridge rectifier
diode(s)
Part details: MR752 6A 200V
Rectifier diode (Linn Part no:
MISS 010)

Содержание LK260

Страница 1: ...OUT THE LK2 SERIES 2 HOW TO DIFFERENTIATE BETWEEN TYPES OF LK2 2 ABOUT THIS MANUAL 3 RETAILER DISTRIBUTOR OBLIGATIONS 3 SPARE PARTS AVAILABILITY AND LK2 REPAIR 3 HOW TO USE THIS MANUAL 3 IMPORTANT SAF...

Страница 2: ...LK2 There are several methods of determining the specification of an LK2 Looking at the serial number of a unit and using the LK2 Product History accessible via Linfo website Product Information will...

Страница 3: ...product until 5 years after the final build We take this obligation very seriously and also go much further Beyond this date we will repair any Linn product that we possibly can where it is within our...

Страница 4: ...nal leads of such products careful routing of the cable may be required Although the LK2 can usually be stacked along with other products with no problem it is better if possible to keep it apart from...

Страница 5: ...p so that it is standing on one of the heatsinks Each channel is held into the tray by 2 countersunk screws that attach to the heatsink on the underside Hold the channel that is now uppermost to preve...

Страница 6: ...p between the board and the heatsink and then slide the board to one side If the board will not move easily check that you have loosened all 5 nuts bolts If all are loosened correctly and it is still...

Страница 7: ...hat all the bolts pass through their respective holes on the board some readjustment is usually necessary Screw the nuts onto the bolts but do not tighten fully Adjust the position of the board with r...

Страница 8: ...entral position Line up the screw holes in the board with those in the heatsink and screw in all four screws but do not tighten fully Line up the board and heatsink so that they are parallel and level...

Страница 9: ...ding and does not take as long as you might think about 20 minutes per board Just measure the impedance across all 3 junctions Emitter Bass Emitter Collector Bass Collector of every transistor on the...

Страница 10: ...uts as these voltage drops also sometimes cause the house lights to dim Consult an electrician or your electricity supply company Doesn t power up or Powers up display LED lit but no function or Possi...

Страница 11: ...240 for 240V mains Our stock of these transformers is very limited so it may not be possible to supply the part you require Fuse blowing May be intermittent but usually constant Transformer faulty To...

Страница 12: ...ance If in doubt compare with good channel See Introduction to Fault Finding section accessible via Linfo Website Product Information for tips on how to isolate faulty board Replace faulty capacitor P...

Страница 13: ...hmmeter to check if faulty usually internal short circuit across one or more of the junctions but also there is the possibility that the transistor measures okay but is indeed faulty It will sometimes...

Страница 14: ...005 Q24 Q31 TIP35C NPN 160V 15A TO218 Linn part no TRAN 004 No output from one channel May be intermittent Regulator U1 or U2 faulty Replace faulty regulator part details U1 LM317T Voltage regulator L...

Страница 15: ...ed as protection and the LK2 may be tripping for a very good reason If tripping occurs continuously or even occasionally it may be because the LK2 is doing its job correctly and something within the s...

Страница 16: ...rule out this fault Check replace power transistor s Part details Q20 Q27 2SA1386 PNP 160V 15A TO218 Linn part no TRAN 017 Q24 Q31 2SC3519 NPN 160V 15A MT100 Linn part no TRAN 018 Tripping Applies on...

Страница 17: ...t Probably intermittent may be temperature dependent Transistor in circuit faulty junction is breaking down See Introduction to Fault Finding accessible via Linfo Product Information Or See Fault Find...

Страница 18: ...ll protect the LK2 from similar potential failures in the future by using higher wattage resistors than were originally used and adjusting the position of some components to minimise heat damage It is...

Страница 19: ...kerchiefs or paper towels Heatsink compound a white grease like substance that improves heat conduction Fine Pliers Soft cloth Parts Required 20Kohm 2 5Watt resistor Qty 2 per unit 2 4Kohm 2 5Watt res...

Страница 20: ...ng on one of the heatsinks Each channel is held into the tray by 2 countersunk screws that attach to the heatsink on the underside Hold the channel that is now uppermost to prevent it from falling onc...

Страница 21: ...between the board and the heatsink and then slide the board to one side If the board will not move easily check that you have loosened all 5 nuts bolts If all are loosened correctly and it is still no...

Страница 22: ...de down and you will see that the capacitor holder is held by two nuts bolts Remove the two nuts and the capacitor will come away from the board but be careful as it will still be held by a pair of wi...

Страница 23: ...le of the board As shown in picture above Bend C6 away from Q10 towards the 3 pin cannon socket As shown in picture above Bend C19 away from Q10 towards R49 but do not bend it too close to R49 positio...

Страница 24: ...was attached to heatsink by nuts bolts follow the instructions below Remove all five bolts from the board and slide the bolts into the slots arranged as shown below Place the board onto the heatsink...

Страница 25: ...not tighten Rest the board on the heatsink in a central position Line up the screw holes in the board with those in the heatsink and screw in all four screws but do not tighten fully Line up the board...

Страница 26: ...ponent on every Linn circuit board has an individual identification code known as a Component Designator C001 Q012 R345 etc The designator shown in the table matches that printed on the circuit board...

Страница 27: ...UMBER EXISTS FOR THIS PART STC TAG THOMSON 1 00000 ONES R C008 NO INFO 33UF 10 10 63V PEST TH PCO200 C N Y NO LINN PART NUMBER EXISTS FOR THIS PART STC TAG THOMSON 1 00000 ONES R C009 CAP 068 100NF 10...

Страница 28: ...90 1 00000 ONES R D002 MISS 001 TYPE FUNCTION CASE C N Y 1N4148 DIODE 1 00000 ONES R D003 MISS 001 TYPE FUNCTION CASE C N Y 1N4148 DIODE 1 00000 ONES R D004 MISS 001 TYPE FUNCTION CASE C N Y 1N4148 DI...

Страница 29: ...E 753 C N Y ZETEX 1 00000 ONES R Q004 TRAN 002 ZTX753 PNP 100V 2A ELINE 753 C N Y ZETEX 1 00000 ONES R Q005 TRAN 001 ZTX653 NPN 100V 2A ELINE 653 C N Y ZETEX 1 00000 ONES R Q006 TRAN 001 ZTX653 NPN 10...

Страница 30: ...PNP 160V 15A MT100 1386 C N Y SANKEN 1 00000 ONES R Q021 TRAN 002 ZTX753 PNP 100V 2A ELINE 753 C N Y ZETEX 1 00000 ONES R Q022 TRAN 002 ZTX753 PNP 100V 2A ELINE 753 C N Y ZETEX 1 00000 ONES R Q023 TR...

Страница 31: ...1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R003 RES 021 100R 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R004 RES 078 4K3 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R005 RES 017 4K7 1 MF 1 4...

Страница 32: ...ppm C N Y 1 00000 ONES R R020 RES 043 180R 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R021 RES 035 1K1 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R022 RES 035 1K1 1 MF 1 4W 0 25W 200V 50ppm...

Страница 33: ...038 2K2 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R039 RES 058 33K 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R040 RES 017 4K7 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R041 RES 002...

Страница 34: ...4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R053 RES 009 27R 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R055 RES 009 27R 1 MF 1 4W 0 25W 200V 50ppm C N Y 1 00000 ONES R R056 RES 048 12R 1 MF 1 4W 0...

Страница 35: ......

Отзывы: