Installation Guide E1100
X6:
Digital I/O (only available on E1100-GP (-HC, -XC))
DSUB-25 (f)
All Inputs:
Direct interfacing to digital 24VDC PLC outputs.
Input Current:
1mA
Sample Rate:
1ms
Low Level:
-30 to 8.5VDC
High Level:
20.5 to 30VDC
All Outputs:
Short circuit and overload protected high side switches
Voltage:
24VDC
Update Rate
1ms
Max. Current:
100mA
Peak Current:
370mA (will shut down if exceeds)
Outputs may directly drive inductive loads. Do not connect any capacity because of the peak current!
X7 - X8
RS485/CAN
1
2
3
4
5
6
7
8
case
R
A
RS485_Rx-
B
R
Y
GND
GND
RS485_Tx-
Z
CAN_H
CAN_L
Shield
RJ-45
Use twisted pair (1-2, 3-6, 4-5, 7-8) cable for wiring.
The built in CAN and RS485 terminations can be activated by S3.2 and S3.3.
X7 is internally connected to X8 (1:1 connection)
X9:
Profibus DP (only available on E1130-DP (-HC, -XC))
1
2
3
4
5
6
7
8
9
case
Not connected
Not connected
RxD/TxD-P
CNTR-P
GND
(isolated)
+5V
(isolated)
Not connected
RxD/TxD-N
Not connected
Shield