p.22 | 23
PBX current I
0
k - dial
Feature is off
0
20mA-50mA
1
45mA-75mA
2
Parameter Value
Description
Default
70
uu
Transmission signaling level in [-dBm]
(04-16)
10
uu – transmission signaling level to the line, range -4 to -16dBm. You insert desired level, uu=04 is -
4dBm, uu=10 is -10dBm ...
6.7. Time program – automatic DAY/NIGHT switching
Parameter
Value
Description
Default
09
a
ON / OFF automatic DAY/NIGHT
switching and setting time control
(0/1/#)
0
When door intercom Link Ana iDP includes RTC circuit. You can activate automatically switching from real
time a=1. The condition is correct time settings. You can verify it easily by dialing a=# and door intercom
reply either by confirmation tone (all is correct) or error tone (you have to setup the time). By dial a=0
you deactivate automatically switching.
Parameter
Value
Description
Default
081
hhnn
Time settings hh-hours, nn-minutes
-
082
ddmmyy
w
Date settings dd-day, mm-month, yy-
year,
w-weekday
-
083
#
Wait 1 min for seconds zeroing
-
Internal clocks Parameters setting. After setting by command 083# zeroing seconds setting any through
this agreed clocks exactly up seconds.
w - weekday: 0 - Sunday
1 - Monday
2 - Tuesday
3 - Wednesday
4 - Thursday
5 - Friday
6 - Saturday
Example: you want set 27.5.2011 9:39 (its Friday), then dial sequence:
0822705115 you hear tone, then dial 0810939 hear tone and finally dial 083 – wait for exact time sec=0 .
In this moment dial # and you hear tone - finished.