p.13 | 23
Note. The command or password for relay 1 start whole sequence. When you use command or password
for relay 2 then you control relay 2 only the same like in mode m=1.
m=6 closed up pushed button (setup in Parameter 31r*). Due this you can select one button for every
relay its pushing activate appropriate relay for time t1/t4. This mode serves as substitution of ring
bell connected to Link Ana iDP system.
m=7 permanent closing / opening –if switching (DIP 3,4)+par.64. By command for pulse 1 is closed
and for pulses2 is opened. This stage stays in door intercom even after power/line disconnection.
This mode you can use for potting, glasshouse opening, heating activation etc..
m=8 activated up DAY/NIGHT mode settings - if switching (DIP 3,4)+par.64. Version allows copying
manual DAY/NIGHT switching only. The Link Ana iDP allows copying setting from week table
switching time (when is activated - Parameter 084) and then you can use for example for heating
control etc…
Paramet
er
Value
Description
Default
31
r* tt
Button tt start relay closing r in mode
m=6
(01-99)
01
r – relay number [1-2]
tt – button number (memory), always has 2 digits [01-99]
This Parameter is for relay mode m=6 only. Value of tt designate from which button start closing for time
t1/t4 of relay r.
Paramet
er
Value
Description
Default
32
rp hh...
In mode DAY + NIGHT password
hh... for relay r, in order p=1-5, for 1
pulse and p=* for 2 pulses
(00-999999)
-
33
rp hh...
In mode DAY password hh... for
relay r, in order p=1-5, for 1 pulse
and p=* for 2 pulses
(00-999999)
-
34
rp hh...
In mode NIGHT password hh... for
relay r, in order p=1-5, for 1 pulse
and p=* for 2 pulses
(00-999999)
-
r
– relay number [1-2]
p
– order [1 - 5] for 1 pulse. 5 passwords (external codes) from door intercom buttons (external
code of code lock)
p
– order = *, then you can insert just one code (external code) for closing by 2 pulses
hh... – password (external code) for relay closing from buttons [2 to 6 digits]. 1 - 10 are programmable
as numbers 1-0.
Totally 3 x 12 passwords. Controlled by settings DAY/NIGHT. Combination is inserting by door
intercom buttons
.
Relay closing is influenced by setup relay mode and switching DAY/NIGHT. When is
a setup mode 2 group of numbers the door intercom is permanently in mode DAY.
You have to keep certain rules for password dialing:
First button of password select from at least used button for direct dialling (-prolong dial time)
Caution on numbers identity of password. When one password includes other, for example:
password for relay1 is 1234 and for relay 2 12345, then always after pushing button 4 relay 1
will be activated and relay 2 wont be never activated. When you select password for relay 2 234,
then after button 4 pushing both relays will be activated.
Note1. Switching to DAY/NIGHT mode stays setup in door intercom even after power (line)
disconnection. At version (C), when is activated, then DAY/NIGHT switching is done up time and week
table.
Note2. when you insert Parameters 32, 33, 34 do not use character # and * because you cant select
them from button panel. Number 0 represents button 10.