p.16 | 23
Parameter Value
Description
Default
43
g bb
End call (00-99,*0-*9)
155
g – command order [1-2] (they are two to be possibility hang up the Link Ana iDP when each relay is
used)
bb – command to and call by phone [2 digits]
It is profitable setup the same command to hang up the Link Ana iDP as same as activate relay
(Parameter 35)
Note: The command has always 2 digits but if you want use 1 digit then you have possibility insert "*a"
where a is just one number.
Parameter Value
Description
Default
44
xxxx
Service password (0000-9999)
0000
xxxx – service password for entry to programming by phone (DTMF)
Parameter Value
Description
Default
45
dd
Day mode switching
(00-99,*0-*9)
11
46
nn
Night mode switching
(00-99,*0-*9)
10
dd – command to switch into DAY mode [2 digits]
nn – command to switch into NIGHT mode [2 digits]
Note. The switchover to Day/Night mode remains set in unit even after line disconnection.
Parameter Value
Description
Default
47
e
Dialing mode (0/1)
1
e – operating mode of unit
e=0 for 2 Group mode, e=1 for Day/Night mode.
Parameter Value
Description
Default
4*
k
End call by push again the same button
(0/1)
1
k – line hanging up by push of same button:
k=0 feature is switch off
k=1 again button push hang up the line
6.4. Time parameters
Parameter Value
Description
Default
51
q
Number of rings before picks up (1-9)
2
q – number of incoming call rings .
Parameter Value
Description
Default
52
d
Maximal call duration (0-9,*,#)
2