p.14 | 23
Parameter Value
Description
Default
35
r aa
First code aa from phone for relay
activating r (00-99,*0-*9)
1 55
36
r cc
Second code aa from phone for relay
activation r (00-99,*0-*9)
1 50
r – relay number [1-2]
aa – command (internal code) from phone for relay activation [2 digits] /
1
For both relays you can setup the same command (internal code) then both relays are activated
simultaneously. It is profitable to setup the same command for relay activation as same as door
intercom hang up (Parameter 43) aa=bb.
/
1
– command has always 2 digits but when you want control relay by 1 digit only (from keypad of
phone) then you have possibility to programm " *a " where a is one number only which activate the
relay (star represents empty character and must be on first digit position).
Example: 1 relay activated by internal code 48 - dial 35148
♫
2 relay activated by internal code 8 - dial 352*8
♫
By dialling on phone 8 you activate relay 2 by dialing 48 you activate both relays
Parameter Value
Description
Default
37
r ss
Relay closing time (01-99)
105
r – relay number
ss – duration of relay closing [2 digits 01-99]. (time 00 means 0,5sec)
Parameter Value
Description
Default
38
r p
Control relay r during incoming call
(0/1)
11 21
r – relay number [1-2]
p – Parameter which says permitted p=1 or forbidden p=0 control relay during incoming call
To prohibit control of relay during incoming call has a sense for example by relay2 in mode 1 by which
you control sliding gate opening where door intercom open the gate and after car passing the gate is
closed. Then control by phone could make unwillingly permanent gate opening.
Parameter Value
Description
Default
39
xx
time xx [sec] between activation relay
1 and 2 in mode m=5 - time t3
(01-99)
10
xx – time t3 between activation relay 1 and 2 when mode m=5 is setup (progressive opening) [2 digits
00-99] ], when time 00 means 0,5sec
Parameter Value
Description
Default
30
r zz
time zz [sec] between pulses when is
closing for 2 pulses relay r - time t2/t5
(00-99)
105 205
r – relay number [1-2]
zz – time t2 / t5 between first and second pulse relay activation 1 / 2 [2 digits 00-99], where 00
means 0,5sec
Parameter Value
Description
Default
3#0
p
p = 1 enabled / disabled p = 0
connection code relay COSW
(0/1)
0
p – turns on transmission serial code to activate the first switch.
CAUTION - at activation this function never connects to the circuit electric lock without board COSW -
code relay - threatens to destroy the relay in Link Ana iDP communicator!