background image

 

 

p.17 | 23 

– Maximum time in minutes for which a call may last. This time can be extended during a call by 

dialing Prolong Call digit from telephone (

 or #). Time setting is per table.

 

 

 

 

 

Parameter  Value 

Description 

Default 

53 

Time between button push                     

(1-9) 

w  – maximal time [sec] between button push [range 1-9] 

relay closing –  if time between two next presses is bigger than w  time, the code is not evaluated 

correctly. 

 

 

Parameter  Value 

Description 

Default 

54 

On hook time before new call (1-5) 

z – time [sec] for which the unit will hang up, before repeat dialing (button pressing during call or 

dialling, busy tone detection) [range 1-5] 

 

 

Parameter  Value 

Description 

Default 

55 

Call start time (1-5) 

z – time [sec] after unit goes on hook before dialing [range 1-5]. This time is different for each PBX, but 

most PBXs usually manage to process dialing up to 2 seconds after line on hook. 

 

Parameter  Value 

Description 

Default 

56 

hh 

Number of rings before hanging up or 

group mode switching. (04-99) 

12 

h – specifies the amount of time spent ringing before the unit hangs up and tries the next number. 

 

Parameter  Value 

Description 

Default 

500 

Middle frequency of tones detector (1-0) 

(375-475Hz) 

501 

Number of busy tones                      (2-

0) 

4  

502 

Time of permanent tone duration      (1-

5) 

3 (3s) 

 x – middle frequency of tones detector – is suitable when PBX signaling is unusual: 

 

y  –  minimal number of busy tones necessary for detection [2-0], where 0 means 10 busy tones 

z  –  minimal time of permanent tone duration (for dial tone detection on PBX) [1-5 sec] 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

frequency 

[Hz] 

x - dial 

275-375 

325-425 

375-475 

425-525 

475-575 

525-625 

575-675 

625-725 

675-775 

725-825 

Содержание Link Ana iDP

Страница 1: ...1 Link Ana iDP Manual v1 0 Please find the latest version of the manual and firmware at www linkcom fr...

Страница 2: ...control 8 4 4 Telephone Caller 10 4 4 1 Outgoing call 10 4 4 2 Incoming call 10 5 Parameter programming 10 5 1 Programming from a telephone by DTMF 10 5 1 1 Parameter programming 10 5 2 PC programming...

Страница 3: ...is possible only with external power supply Don t forget setup Parameter 64 Connection of door intercom to certain type of PBX which has problems with current consumption on its extensions during star...

Страница 4: ...2 1 Opening the door phone Using the tool provided unscrew the screw as shown below and remove the cover 2 2 Dismounting of nameplate Remove the 4 screws of the transparent protection Make the appropr...

Страница 5: ...ace mounting Using 3 screws and plugs fix the doorphone to the wall 3 3 Flush mounting The dimensions of the flush part are Height 182mm Width 104mm Depth 22mm Using 3 screws and plugs fix the doorpho...

Страница 6: ...ted inversely fire emergency exit 3 Combination of doors with electrical lock and sliding gate at fencing 4 Extending of previous example 3 about second doors with progressive opening this feature is...

Страница 7: ...ion Samples of acoustical sounds you can play in Link Ana Manager Stage Tones Tone frequency Line pick up OFF HOOK type 1 980 1333 1650 Line hang up ON HOOK type1 1650 1333 980 Line pick up OFF HOOK t...

Страница 8: ...r parameter 42 to prolong the call The dialed number is dictated by the chosen mode which is set in the unit parameter 47 Day Night mode If the unit is in Day mode it will always dial the number set i...

Страница 9: ...ns 3211 3215 According settings DAY NIGHT 3311 3315 3411 3415 3221 3225 According settings DAY NIGHT 3321 3325 3421 3425 321 According settings DAY NIGHT 331 341 322 According settings DAY NIGHT 332 3...

Страница 10: ...irectly without dialing service password During an incoming call it is possible to restrict relay control This can be useful in some special applications 5 Parameter programming 5 1 Programming from a...

Страница 11: ...ccasionally press a key e g or 7 The unit will respond with an error tone but the connection will be kept alive Note 2 The sign is not used in the values for parameters 32 33 and 34 and can be used to...

Страница 12: ...ivated by command internal code or password external code 1 pulse for time t1 t4 using for electrical locks or 2 pulses when is activated for time t1 t4 open for time t2 t5 and close for time t1 t4 sl...

Страница 13: ...rp hh In mode DAY password hh for relay r in order p 1 5 for 1 pulse and p for 2 pulses 00 999999 34 rp hh In mode NIGHT password hh for relay r in order p 1 5 for 1 pulse and p for 2 pulses 00 999999...

Страница 14: ...er Value Description Default 38 r p Control relay r during incoming call 0 1 11 21 r relay number 1 2 p Parameter which says permitted p 1 or forbidden p 0 control relay during incoming call To prohib...

Страница 15: ...iDP sends a serial code for the code relay COSW after evaluation code from keys keyboard namely for 2 pulses Parameter Value Description Default 3 4 abcd Activation code 2 pulses from phone 0000 1111...

Страница 16: ...lue Description Default 45 dd Day mode switching 00 99 0 9 11 46 nn Night mode switching 00 99 0 9 10 dd command to switch into DAY mode 2 digits nn command to switch into NIGHT mode 2 digits Note The...

Страница 17: ...s on hook before dialing range 1 5 This time is different for each PBX but most PBXs usually manage to process dialing up to 2 seconds after line on hook Parameter Value Description Default 56 hh Numb...

Страница 18: ...duration time ms range 1 6 correspond to 100 600ms p Time of pause duration is calculated Inserted number x 100 400 pause duration time ms Range 1 0 correspond to 500 1400ms Time p is also time of pau...

Страница 19: ...wer supply is OFF Activation has a sense only in cases when door intercom should make some operation during stand by mode relay activation Relay in mode m 7 allows permanent closing even after call te...

Страница 20: ...s feature t 1 is processor going to sleep mode after line connection and after 3sec the door intercom makes initialization It delays line picks up after line voltage connection activation status PBX r...

Страница 21: ...vity is In noisy environment we recommend higher value with combination of parameters 71 75 77 Parameter Value Description Default 77 s Fast switching voice automatic 1 4 4 is slowest 2 At Parameters...

Страница 22: ...ify it easily by dialing a and door intercom reply either by confirmation tone all is correct or error tone you have to setup the time By dial a 0 you deactivate automatically switching Parameter Valu...

Страница 23: ...Default settings only for parameters 3x 84 Default settings only for parameters 4x 85 Default settings only for parameters 5x 86 Default settings only for parameters 6x 87 Default settings only for pa...

Страница 24: ...andwidth 300Hz 3400 Hz 20 60mA Ringing impedance 2Kohm 25 60 Hz Sensitivity of ringing detector min 10 25 V Pulse dial 40 60 ms Tone dial level 6 and 8 dB 20 60 mA Sensitivity of tone dial min 40 dB 2...

Отзывы: