iGrow 1800 Installation Guide
Page70
Link4 (714) 524-0004
01 Name1 None
This channel has no
selected equipment.
Press the
Enter/Menu
button a second time and you will see the following screen:
01
Name1 None
This channel has no
selected equipment.
This time channel 01 is highlighted. Use the + and – buttons to cycle through all the channels on the controller
or to find the channel that you want to program or edit.
Once the channel is selected, the next two steps are to name the channel (usually named by the equipment
type it’s controlling), and to set what kind of equipment it is.
For un-programmed equipment, there are two editable choices: the name field and the equipment type field.
Press the
Next
or
Ente
r buttons to name the channel. Press the
+
key and the alphanumeric character list is
displayed. Use the
+ or –
keys to select your character and press
Next
to go to the next one. When finished
press the
Back
key. The names are restricted to 5 alphanumeric characters.
Press the
Next
key to select the equipment type to be assigned to the channel. Again use the
+ or –
keys to
cycle through the equipment type field that has the following equipment types:
On/Off
– On/Off may be programmed on any channel
Irrig
–
Irrig may be programmed on any channel
CO2
–
CO2 may be programmed on any channel
Light
– Light may be programmed on any channel
MZone
– MZone (or Microzone) is an On/Off type device with its own setpoints and temp sensor (temp probe
only). It is an independent thermostat output with Day/Night settings. It can be programmed on any
Channel.
Pump
- Pump may be programmed on any channel.
G PID-
This
Generic PID
controller may be programmed on any output
.
Vent
–
Vent may only be programmed on any two consecutive channels, the first channel being an odd
number and the second it’s neighboring even number (for example: channels 1&2 or 3&4 are
acceptable pairs, but 2&3, or 8&9 are not)
Curtain
– Curtain may only be programmed on any two consecutive channels, the first channel being an odd
number and the second it’s neighboring even number (for example: channels 1&2 or 3&4 are
acceptable pairs, but 2&3, or 8&9 are not)
MixV
–
MixV may only be programmed on any two consecutive channels, the first channel being an odd
number and the second it’s neighboring even number (for example: channels 1&2 or 3&4 are
acceptable pairs, but 2&3, or 8&9 are not)
PZone
– PZone (In some versions this is referred to as PZONE) is a special purpose Mixvalve, and is a
proportional controlled MicroZone. It may only be programmed on any two consecutive channels,
the first channel being an odd number and the second it’s neighboring even number (for example:
channels 1&2 or 3&4 are acceptable pairs, but 2&3, or 8&9 are not) It is an independent thermostat
output that can control modulating heat valves.
VOut
– VOut is a variable voltage or current output for equipments such as variable speed fans. This option
only appears if you have installed the optional iMOD (Multi-Output Device) expansion board.