Setup Inputs (sensor mapping)
InT
⇚
SerialSns1
OutT
⇚
SerialSns2
RelHum
⇚
SerialSns1
CO2
⇚
AnalogIn6
OLight
⇚
Solar
InLight
⇚
None
WinSpd
⇚
FDIn1
WinDir
⇚
AnalogIn7
Rain
⇚
FDIn2
Snow
⇚
None
BkUp InT
⇚
None
Pressure
⇚
None
IrrTrig
⇚
DigitalIn1
OutHum
⇚
SerialSns2
Temp1
⇚
AnalogIn1
Temp2
⇚
AnalogIn2
Temp3
⇚
AnalogIn3
Temp4
⇚
AnalogIn4
Temp5
⇚
AnalogIn5
VPos1
⇚
AnalogIn1
VPos2
⇚
AnalogIn2
VPos3
⇚
AnalogIn3
VPos4
⇚
AnalogIn4
VPos5
⇚
AnalogIn5
pH1
⇚
AnaIn1
pH2
⇚
AnaIn2
pH3
⇚
AnaIn1
pH4
⇚
AnaIn2
5uS EC3
⇚
AnaIn3
Soil1
⇚
None
Soil2
⇚
None
Soil3
⇚
None
Soil4
⇚
None
Soil5
⇚
None
Generic1
⇚
None
Generic2
⇚
None
Locl Tmp
⇚
None
Locl Hum
⇚
None
Setup Inputs is where you tell your iGrow1600/1800™ what sensors you are using (this is also called sensor
mapping). The screen above shows the typical sensor mapping for each sensor. If you don’t have a particular
sensor then leave the setting as
None
.