iGrow 1800 Installation Guide
Page96
Link4 (714) 524-0004
Note:
If you have installed the iMOD expansion module but don’t see VOut as an equipment option, you must
Enable
“Expansion Settings” before it will appear as available equipment. You will have to go back to the
first programming screen and scroll down to the Expansion Settings option.
Variable Current
Outputs
For outputs that you have configured in Expansion Settings as Variable Current devices, the following
screens appear.
15 VFan1 VOut
Current varies with
Ht Dem
Ht Dem
This field determines whether the equipment connected to this output is for heating or cooling.
Ht Dem
is for
heating and
Cl Dem
is for cooling.
15 VFan1 VOut
Ht Dem mAmps
Max 0 20.00
Min 0 20.00
Max
Max
is the heat demand percentage that you want the maximum output level to occur at. The value to the right
of
Max
sets the current output that occurs at the
max
percentage.
Min
Min
is the heat demand percentage that you want the minimum output level to occur at. The value to the right
of
Min
sets the current output that occurs at the
min
percentage.
15 VFan1 VOut
Offset Cal 0.00
Gain Cal 1.00
Offset Cal
Gain Cal