52
Copyright 1993 Link Communications
In Depth Command Description: C036
Message Program Utility
This command allows programming of the many messages on the RLC-1. Messages 1..6 are be
CW (Morse Code), 7..8 execute the specified command. Refer C037 for the message numbers
and maximum lengths.
Description
Command
CW Response
Program Message
C036*$ %% .. %%*
See Below
Parameters:
$ is a one-digit code (0..8) representing the number of the message you wish to program.
%% - This data must be 2 digits long per CW Character, up to the maximum message
length (see C037), or 4 digits long if it is a command name (messages 7 and 8 only). See CW
Tables for Character list.
Example: To Program 'KF7FW / R' for the Main Port ID
C036*1 20 15 07 15 32 36 27 *
K F 7 F W / R
Example: To change the Main CW Beep Frequency when Input #4 goes from Low-High. Also
we will change the frequency back when Input #4 goes from High-Low. This could be used as an
open door alarm.
1) Use Macro #1 to change the frequency on a Low-High condition
2) Use Macro #2 to change the frequency on a High-Low condition
3) Macro #1 Program: C032 * 1 C014 0500 *
4) Macro #2 Program: C032 * 2 C014 1000 *
5) Low-High Command Name Call: C036* 8 C025 *
6) High-Low Command Name Call: C036* 7 C026 *
Error Messages:
If the format is not correct, the RLC-1 will send a "E" error code.
ER1 - No Such Message
ER2 - Too Many Digits Entered for Selected Message
Содержание RLC-1
Страница 19: ...15 Copyright 1993 Link Communications Other Analog Input Examples...
Страница 75: ...71 Copyright 1993 Link Communications Schematic Diagrams...
Страница 76: ...72 Copyright 1993 Link Communications...
Страница 77: ...73 Copyright 1993 Link Communications...
Страница 78: ...74 Copyright 1993 Link Communications Board Layout...