10
Copyright 1993 Link Communications
Serial Commands Entry Format:
- All Serial Commands begin with the Letter "S"
- The Commands number from 00 .. 05
Serial Commands:
S00 - Dump of Command Names
C000 : C001 : C002 : .. C042:
S01 - Formatted Dump of the Output Lines, Input Lines, and Analog Lines
Outputs:
1 - N or F
2 - N or F
3 - N or F
4 - N or F
5 - N or F
Inputs:
1 - H or L
2 - H or L
3 - H or L
4 - H or L
Analog:
1 - Actual Dump of programmed Value
2 - Actual Dump of programmed Value
3 - Actual Dump of programmed Value
4 - Actual Dump of programmed Value
S02 - Dump of Selected Macro Position
Example: Two output lines turned on with one command
[
Macro 1:
C017 Plus 01:01
C017 Plus 02:00
]