In Depth Command Description: C037
Message Read Back Utility
This command reads back the preprogrammed CW (Morse Code) messages. This helps in
determining what messages are programmed in without having to re-program them.
Description
Command
CW Response
Read Message
C037*$*
See Below
Parameters:
$ is a one-digit code representing the number of the message you wish to recall.
Message Number Description
Maximum Length
0
RLC-1 Version
20 CW Characters
1
Main Port ID
20 CW Characters
2
Link Port ID
20 CW Characters
3
Link ON
20 CW Characters
4
Link OFF
20 CW Characters
5
Link MON
20 CW Characters
6
CW Response Message
5 CW Characters
7
Input #4 High-Low Command
1 Four Digit Command
8
Input #4 Low-High Message
1 Four Digit Command
Error Messages:
If the format is not correct, the RLC-1 will send a "E" error code.
ER1 - No Such Message