13
dc1540bf
DEMO MANUAL DC1540B
DC1361B - CHANGING THE NOMINAL OUTPUT VOLTAGES
The Nominal V
OUT
of any channel on the DC1361B can be
changed by changing the R
SET
resistor from V
FB
to SGND.
These are: R21, R26, R29, R38, R48, R67, R73, R79. See
Figure 9. The value for the R
SET
resistor is:
R
SET
= 60.4k/((V
OUT
/0.6) –1))
See also the LTM4603 datasheet Table 2. V
OUT0
may be
adjusted up to 5V. The other channels may be adjusted
up to 4V.
Figure 9. DC1361B Output Voltage Setting Resistor Locations