Chapter 3 |
9
Installation and Initial Setup Using the Front Panel Interface
The Home Screen
The IP address of the network Control port (used to connect to the remote user interface) is shown in the lower
left corner. If a network connection is detected, the IP address will be yellow. If there is no network connection, the
IP address will be red.
The primary reference clock source and status is shown in the lower right corner. Green indicates an active solid
reference. Red indicates an inactive or missing reference.
Figure 3-1 – Front panel Home screen
The Information Screen
Pressing the Right button navigates to the Information screen.
The name of this particular LA-5291 and its location are displayed at the top of the screen. These values can be
customized using the remote interface as detailed in Chapter 6.
The unit’s unique serial number is shown next, followed by the current firmware version, the IP address of the
Control port (the port used to connect to the remote interface), the IP address of the AES67 port (the port used to
carry AES67 AoIP), and the current active clock reference.
Figure 3-2 – Front panel Information screen