23.  INSPECTION BEFORE EVERY USE:

1.  Visual check. 

2.  Lead-in cable check. 

3.  Condenser cleanliness check (in case of excess pollution of the condenser, clean more 

frequently than 1x a month).

 WARNING:

   

Do not use the device if defects or malfunctions are found.

24.  PERIODIC CHECKS: 

 1x a week: check that the lead-in cable is 

undamaged and that the plug is firmly in the 

socket.  

  1x a week: check that the device is not 

exposed to radiant heat.  

  1x a week: check that air circulation is not 

obstructed.

 

 1x a month: check the cooling unit‘s con-

denser and clean it regularly.

  1x a year: have an engineering inspector 

check the electrical safety of the device.

22.  MAINTENANCE:

Flush the beverage tubing of the cooler after 

each use with pressurised water (see Sanita-

tion by Water). To make flushing easier, use 

a sanitation adapter according to your type 

of keg coupler (not included in standard ac-

cessories). The cooler must be sanitised once 

every 14 days by a person with chemical engi-

neering qualifications. The condenser must be 

checked for cleanliness every month. Any dirt 

found must be cleaned with compressed air or 

wiped off. Otherwise, there is a risk of reduced 

cooling output or damaging of the cooler.

25.  ENVIRONMENTAL PROTECTION:

Waste Sorting:

This product must not be disposed of in communal waste. Electrical waste in the Czech 

Republic is disposed of within the Rema System (www.remasystem.cz).

In countries other than the Czech Republic, waste sorting is subject to local regulations.

Sorting waste allows recycling and reusing used products and packaging materials. Reuse 

of recycled material helps protect the environment from pollution and reduces resour-

ce consumption. Local regulations may regulate the method of disposing of household 

appliances at local collection points or at the point of sale.

Содержание KONTAKT 55

Страница 1: ...LINDR FLOW TYPE LUXURY COOLER Number 014 2020 REV00 Valid 2020 07 01 INSTRUCTION MANUAL ENGLISH...

Страница 2: ...ains important information necessary to ensure that all operations are done pro perly and safely WARNING Not following instructions may cause injury or damage the device SYMBOLS AND MARKINGS USED IN T...

Страница 3: ...Keg coupler assembly 12 Beverage supply connection and pressurisation 13 Beverage connections 14 Positioning of the thermostat 15 How to work with speed fittings 16 Temperature and adjustment 17 Keg t...

Страница 4: ...ect use DO NOT USE THE DEVICE FOR PURPOSES OTHER THAN THOSE STATED BY THE MANU FACTURER General safety principles Observe the fo llowing safety instructions The supplier is not liable for damage cause...

Страница 5: ...NING Do not use open flame or po tential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the coo ler so that heat created by the cooling unit can be vent...

Страница 6: ...nstructi on manual or the product s design as defined by the manufacturer Materials replaced du ring the validity period of the warranty are our property The legitimacy of the warranty claim is always...

Страница 7: ...ed onto the bushing and affixed with a clip figure 7 A figure 7 b figure 7 E 1 Turn the compensator lever 1 so that it points down see figure The compensator lever on the tap is used to adjust the flo...

Страница 8: ...ng onto the keg coupler figure 8 A figure 8 b figure 8 c figure 8 d WARNING Before you screw the speed fitting onto the 5 8 thread make sure the keg coupler air inlet for delivery medium has a lip val...

Страница 9: ...3 Compressor switch 4 Keg coupler A system S system M system 5 F 5 8x9 5mm speed fitting 6 F 5 8x8mm speed fitting 7 Beverage 12 2 Connection and Pressurisation by CO2 Bottle One Tap Device 1 Beverage...

Страница 10: ...eed fitting 6 F 5 8 x 8 mm speed fitting 7 Y 8 x 8 x 8 mm speed fitting 8 Beverage 12 4 Connection and Pressurisation by Classic CO2 Bottle Two Tap Device 1 Beverage inlet 2 Keg coupler A system S sys...

Страница 11: ...The set pressure will be displayed on the pressure gauge in bars The compressor can be turned off separately with a switch The air outlet from the cooler terminates in a 5 16 8 mm speed fitting marked...

Страница 12: ...figure 12 B 14 POSITIONINGOFTHETHERMOSTAT 14 1 Positioning of the thermostat SOUDEK 20 Green Line Mechanical thermostat is located under the wooden cap on the back of the cooler figure 12 A 14 2 Posit...

Страница 13: ...2 Speed Fitting Removal Hold the grey ring tight against the body of the speed fitting and pull out the hose figure 13 B WARNING If you do not hold the grey ring but pull at the hose the speed fitting...

Страница 14: ...b figure 14 c figure 14 d figure 14 e 17 KEG TAPPING AND UNTAPPING 17 1 Keg Tapping Procedure for tapping a keg using an S system keg coupler WARNING Make sure the adapter is clean before tapping the...

Страница 15: ...ing a keg using an A system keg coupler A system keg coupler figure 15 d figure 15 e 17 2 Keg Untapping Procedure for untapping a keg using an S system keg coupler figure 15 a figure 15 b figure 15 c...

Страница 16: ...WARNING If a leakage is found untap the keg according to point 17 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are unsure how to proceed contac...

Страница 17: ...iness of condenser plates device overheats place the device in a colder environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg air compressor...

Страница 18: ...ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufacturer Sanitation Procedure Once you have finished a keg...

Страница 19: ...use a sanitation adapter according to your type of keg coupler not included in standard ac cessories The cooler must be sanitised once every 14 days by a person with chemical engi neering qualificatio...

Страница 20: ...50x415x490 34 0 KONTAKT 55 K PROFI GREEN LINE 1 5 510 50 40 10 2 R290 220 240V 50Hz 1 437 1 90 400x430x270 475 33 5 SOUDEK 50 3xKOH GREEN LINE 1 5 510 50 40 10 2 R290 220 240V 50Hz 1 322 1 40 350x415x...

Отзывы: