LINDR KONTAKT 55 Скачать руководство пользователя страница 20

PR

ODUC

MODEL

COOLING 

POWER 

OF THE 

COMPRESSOR

(HP)

COOLING 

POWER 

OF THE 

COMPRESSOR

(W

)

M

AXIMUM  COOLING 

CAP

ACIT

Y (L/

HOUR)T

0°C/TK  45°C

CONTINUOUS 

COOLING 

PERFORM

AN

-

CE

(L/HOD

)

THERM

AL 

GR

ADIENT Δt (°C

)

NUMBER  OF T

APS

(KS)

TY

PE OF 

REFRIGER

ANT

VOL

TA

GE

POWER

(W

)

A

MPER

AGE

(A

)

DIMENSION OF  THE C

ABINE

T

(ŠXHX

V MM)

NE

T

WEIGHT

(K

G)

SOUDEK 20

GREEN LINE

1/8

280

20

15

10

1

R290

220-240V 50H

z~1

253

1,10

200x375x395

13,0

PY

GMY 25/K EX

CL

USIVE 1xK

OH

GREEN LINE  

1/8

310

30

25

10

1

R290

220-240V 50H

z~1

368

1,60

185x300x375

19,0

SOUDEK 50 (

CHR

OM)

GREEN LINE

 

1/5

510

50

40

10

2

R290

220-240V 50H

z~1

322

1,40

350x415x490

32,0

SOUDEK 50/K (

CHR

OM)

GREEN LINE

1/5

510

50

40

10

2

R290

220-240V 50H

z~1

437

1,90

350x415x490

34,0

KONT

AK

T 55/K PR

OFI

GREEN LINE

1/5

510

50

40

10

2

R290

220-240V 50H

z~1

437

1,90

400x475

33,5

SOUDEK 50 3xK

OH

GREEN LINE

1/5

510

50

40

10

2

R290

220-240V 50H

z~1

322

1,40

350x415x490

32,5

SOUDEK 50/K 3xK

OH

GREEN LINE

1/5

510

50

40

10

2

R290

220-240V 50H

z~1

437

1,90

350x415x490

34,0

SOUDEK 50/K PR

OFI  (

CHR

OM)

GREEN LINE

1/5

510

50

40

10 

2

R290

220-240V 50H

z~1

437

1,90

350x415x490

34,0

KONT

AK

T 55

GREEN LINE

1/5

510

50

40

10

2

R290

220-240V 50H

z~1

322

1,40

400x475

31,0

SOUDEK 50/K 4xK

OH

GREEN LINE

1/5

510

50

40

10

2

R290

220-240V 50H

z~1

437

1,90

350x415x490

34,0

SOUDEK 30/K (

CHR

OM)

1/8

280

35

30

10

1

R134a

220-240V 50H

z~1

345

1,50

295x375x415

21,5

PY

GMY 25/K EX

CL

USIVE 1xK

OH

1/8

280

30

25

10

1

R134a

220-240V 50H

z~1

345

1,50

185x300x345

16,5

PY

GMY 25/K EX

CL

USIVE 2xK

OH

1/8

280

30

25

10

2

R134a

220-240V 50H

z~1

345

1,50

185x300x345

17,5

Содержание KONTAKT 55

Страница 1: ...LINDR FLOW TYPE LUXURY COOLER Number 014 2020 REV00 Valid 2020 07 01 INSTRUCTION MANUAL ENGLISH...

Страница 2: ...ains important information necessary to ensure that all operations are done pro perly and safely WARNING Not following instructions may cause injury or damage the device SYMBOLS AND MARKINGS USED IN T...

Страница 3: ...Keg coupler assembly 12 Beverage supply connection and pressurisation 13 Beverage connections 14 Positioning of the thermostat 15 How to work with speed fittings 16 Temperature and adjustment 17 Keg t...

Страница 4: ...ect use DO NOT USE THE DEVICE FOR PURPOSES OTHER THAN THOSE STATED BY THE MANU FACTURER General safety principles Observe the fo llowing safety instructions The supplier is not liable for damage cause...

Страница 5: ...NING Do not use open flame or po tential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the coo ler so that heat created by the cooling unit can be vent...

Страница 6: ...nstructi on manual or the product s design as defined by the manufacturer Materials replaced du ring the validity period of the warranty are our property The legitimacy of the warranty claim is always...

Страница 7: ...ed onto the bushing and affixed with a clip figure 7 A figure 7 b figure 7 E 1 Turn the compensator lever 1 so that it points down see figure The compensator lever on the tap is used to adjust the flo...

Страница 8: ...ng onto the keg coupler figure 8 A figure 8 b figure 8 c figure 8 d WARNING Before you screw the speed fitting onto the 5 8 thread make sure the keg coupler air inlet for delivery medium has a lip val...

Страница 9: ...3 Compressor switch 4 Keg coupler A system S system M system 5 F 5 8x9 5mm speed fitting 6 F 5 8x8mm speed fitting 7 Beverage 12 2 Connection and Pressurisation by CO2 Bottle One Tap Device 1 Beverage...

Страница 10: ...eed fitting 6 F 5 8 x 8 mm speed fitting 7 Y 8 x 8 x 8 mm speed fitting 8 Beverage 12 4 Connection and Pressurisation by Classic CO2 Bottle Two Tap Device 1 Beverage inlet 2 Keg coupler A system S sys...

Страница 11: ...The set pressure will be displayed on the pressure gauge in bars The compressor can be turned off separately with a switch The air outlet from the cooler terminates in a 5 16 8 mm speed fitting marked...

Страница 12: ...figure 12 B 14 POSITIONINGOFTHETHERMOSTAT 14 1 Positioning of the thermostat SOUDEK 20 Green Line Mechanical thermostat is located under the wooden cap on the back of the cooler figure 12 A 14 2 Posit...

Страница 13: ...2 Speed Fitting Removal Hold the grey ring tight against the body of the speed fitting and pull out the hose figure 13 B WARNING If you do not hold the grey ring but pull at the hose the speed fitting...

Страница 14: ...b figure 14 c figure 14 d figure 14 e 17 KEG TAPPING AND UNTAPPING 17 1 Keg Tapping Procedure for tapping a keg using an S system keg coupler WARNING Make sure the adapter is clean before tapping the...

Страница 15: ...ing a keg using an A system keg coupler A system keg coupler figure 15 d figure 15 e 17 2 Keg Untapping Procedure for untapping a keg using an S system keg coupler figure 15 a figure 15 b figure 15 c...

Страница 16: ...WARNING If a leakage is found untap the keg according to point 17 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are unsure how to proceed contac...

Страница 17: ...iness of condenser plates device overheats place the device in a colder environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg air compressor...

Страница 18: ...ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufacturer Sanitation Procedure Once you have finished a keg...

Страница 19: ...use a sanitation adapter according to your type of keg coupler not included in standard ac cessories The cooler must be sanitised once every 14 days by a person with chemical engi neering qualificatio...

Страница 20: ...50x415x490 34 0 KONTAKT 55 K PROFI GREEN LINE 1 5 510 50 40 10 2 R290 220 240V 50Hz 1 437 1 90 400x430x270 475 33 5 SOUDEK 50 3xKOH GREEN LINE 1 5 510 50 40 10 2 R290 220 240V 50Hz 1 322 1 40 350x415x...

Отзывы: