LINDR GREEN LINE KONTAKT 155 Скачать руководство пользователя страница 5

cont

ac

t-cooled dispensing s

ys

tem

 

5

WARNING:

  Never  place  tools  or  other  ob-

ject into the fan.

WARNING:

  Never  touch  electrical  compo-

nents with wet or damp hands.

WARNING:

  To  ensure  the  cooling  unit 

works properly and at full capacity, make sure 

air supply to the unit is not obstructed.

WARNING:

 Water temperature during sani-

tation must not be higher than 25 °C!

WARNING:

  Always  make  sure  the  power 

socket you intend to plug the cooler into is ac-

cessible, so that the appliance can be immedi-

ately unplugged in case of emergency.

WARNING:

  When  unplugging  the  device 

from the socket, grab the plug and pull it out. 

Do not under any circumstances pull at the ca-

ble; risk of damage.

WARNING

: To turn the device o

ff

 complete-

ly, unplug the appliance from the power sock-

et.

 

WARNING:

 In the event the electrical wiring 

of the product becomes damaged, summon a 

trained  service  technician.  Do  not  under  any 

circumstances repair the device yourself.

WARNING:

 

The  cooling  system  contains 

fl

ammable coolant R290 (propane)!

WARNING:

  Emergency  maintenance  and 

repair of the cooling system must be done by 

trained,  authorised  technicians  familiar  with 

cooling and electrical systems. The technicians 

should have special training and quali

fi

cation 

for handling 

fl

ammable substances in order to 

perform  service  on  coolers  containing

 

R290. 

Follow basic regulations and safety measures 

regarding service and repair!

 

WARNING:

  Do not use open 

fl

ame or po-

tential  sources  of  sparks  in  the  vicinity  of  a 

cooler using 

R290

 coolant!

WARNING:

 After unpacking, place the cool-

er so that heat created by the cooling unit can 

be vented su

ffi

ciently.

WARNING:

 Do not place objects that could 

prevent air circulation on top of the cooler.

5. INSTALLATION AND PLACEMENT

Place  the  cooler  onto  a  stable,  level  surface 

(maximum  permitted  inclination:  2  degrees). 

The appliance requires unobstructed air circu-

lation.

•  Ensure su

ffi

cient free space for air circulation 

and heat dissipation.

•  Ensure su

ffi

cient supply of fresh air.

•  The device must not be placed in an enclosed 

space. 

•  The device must not be placed in the vicinity 

of heat sources or exposed to direct sunlight.

Minimum distance of vents from an obstacle 

that would limit air circulation must be 30 cm. 

Minimum  distance  for  sections  with  no  air 

vents is 7 cm. Ideally, use the device in a cool 

and  well-ventilated  room.  The  device  is  de-

signed  for  use  at  ambient  temperature  of  at 

least 16 °C and at most 32°C. 

WARNING:

 

The device MUST NOT be used 

or stored at ambient temperature lower than 

0 °C.

 The device is designed for use in a normal 

environment,  always  under  a  roof,  protected 

from rain or sunlight.  Climate class N. 

 DANGER: 

 Protect the cooler and electrical 

connection from rain and spraying water!

WARNING:

  Do not under any circumstanc-

es lay the cooler on its side, not even during 

transport.

NOTE:

 In order for the device to work 

correctly and at maximum output, it is im-

portant to not cover up any of the device's 

vents and ensure su

ffi

cient air circulation.

Содержание GREEN LINE KONTAKT 155

Страница 1: ...LINDR FLOW THROUGH CONTACT COOLER Number 012 2020 REV00 Valid 2020 06 01 INSTRUCTION MANUAL ENGLISH...

Страница 2: ...ins important information necessary to ensure that all operations are done prop erly and safely WARNING Not following instructions may cause injury or damage the device SYMBOLS AND MARKINGS USED IN TH...

Страница 3: ...allation 11 Keg coupler assembly 12 Beverage supply connection and pressurisation 13 Connection and regulation of KONTAKT 155 R 14 How to work with speed fittings 15 Temperature and adjustment 16 Keg...

Страница 4: ...al safety principles Observe the fol lowing safety instructions The supplier is not liable for damage caused by activities carried out on this device without observing the following instructions WARNI...

Страница 5: ...repair WARNING Do not use open flame or po tential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the cool er so that heat created by the cooling unit c...

Страница 6: ...e instruc tion manual or the product s design as defined by the manufacturer Materials replaced dur ing the validity period of the warranty are our property The legitimacy of the warranty claim is alw...

Страница 7: ...fitted onto the bushing and affixed with a clip figure 7 A figure 7 b figure 7 E 1 Turn the compensator lever 1 so that it points down see figure The compensator lever on the tap is used to adjust the...

Страница 8: ...speed fitting onto the keg coupler figure 8 A figure 8 b figure 8 c figure 8 d WARNING Before you screw the speed fitting onto the 5 8 thread make sure the keg coupler air inlet for delivery medium h...

Страница 9: ...ompressor switch 4 Keg coupler A system S system M system 5 F 5 8x9 5 mm speed fitting 6 F 5 8x8 mm speed fitting 7 Beverage 7 4 5 6 1 2 3 12 2 Connection and Pressurisation by CO2 Bottle One Tap Devi...

Страница 10: ...compressor and GREEN LINE models PYG MY 20 K PYGMY 25 K KONTAKT 40 K KONTAKT 70 K KONTAKT 155 K The air mini compressor is built into the cooling device itself Automatic pressure regulation is set to...

Страница 11: ...e figure 11 a Other Pressurisation Options By PUMA 1HP and 1 2HP compressor LEONARDO 1HP compressor AIRCRAFT 1HP compres sor classic Biogon N2 bottles 12 5 Connecting KONTAKT 155 R to Pressurisation w...

Страница 12: ...pressure gauges located on the front of the cooler 7 Tap the keg using the keg coupler WARNING Check that all joints are sufficiently leak tight after connection If everything is in order check the t...

Страница 13: ...olic beverages set the thermostat knob to 5 at the most otherwise there is a risk of the beverage freezing in the cooler s tubing and damaging the device 14 2 Speed Fitting Removal Hold the grey ring...

Страница 14: ...b figure 14 c figure 14 d figure 14 e 16 KEG TAPPING AND UNTAPPING 16 1 Keg Tapping Procedure for tapping a keg using an S system keg coupler WARNING Make sure the adapter is clean before tapping the...

Страница 15: ...tapping a keg using an A system keg coupler A system keg coupler figure 15 d figure 15 e 16 2 Keg Untapping Procedure for untapping a keg using an S system keg coupler figure 15 a figure 15 b figure...

Страница 16: ...WARNING If a leakage is found untap the keg according to point 16 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are unsure how to proceed contac...

Страница 17: ...leanliness of condenser plates device overheats place the device in a colder environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg air compr...

Страница 18: ...ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufacturer Sanitation Procedure Once you have finished a keg...

Страница 19: ...sier use a sanitation adapter according to your type of keg coupler not included in standard accesso ries The cooler must be sanitised once every 14 days by a person with chemical engineering qualific...

Страница 20: ......

Отзывы: