1. INTRODUCTION: 

Thank you for purchasing this LINDR product.

2. DESCRIPTION OF THE COOLER

This beverage dispensing system with built-in 

compressor  is

 

designed  for  cooling,  dispens-

ing  and  serving  well-cooled  beer  and  bever-

ages.

The  modern  Lindr  compressor  cooling  unit 

uses  input  energy  and  transforms  it  directly 

into cooling, ensuring proper beer cooling at 

minimum energy drain.

This manual is intended for models:

 

PYGMY 30/K pro

fi

 

and

 

GREEN LINE models:

  

PYGMY 20

PYGMY 20/K

PYGMY 25

PYGMY 25/K 

KONTAKT 40

KONTAKT 40/K

KONTAKT 40/K pro

fi

 

KONTAKT 70

KONTAKT 70/K

KONTAKT 155

KONTAKT 155/K

KONTAKT 155/R

3. MACHINE PLATE

4. GENERAL INSTRUCTIONS, MEASURES 

AND SAFETY INSTRUCTIONS

When  using  the  device,  follow  basic  safety 

instructions  stated  by  the  manufacturer. The 

cooling  device  is  designed  for 

fl

ow-through 

cooling of beverages. Any other use is consid-

ered impermissible and therefore dangerous. 

The  supplier  is  not  liable  for  damage  caused 

by incorrect use.

 

DO  NOT  USE  THE  DEVICE  FOR  PURPOSES 

OTHER THAN THOSE STATED BY THE MANU-

FACTURER!

General  safety  principles.  Observe  the  fol-

lowing safety instructions. 

The  supplier  is  not  liable  for  damage  caused 

by activities carried out on this device without 

observing the following instructions!

 

WARNING:

 Children aged 15 or more and 

persons  with  reduced  physical,  sensory  or 

mental  capabilities  or  insu

ffi

cient  experience 

and knowledge may only use the device when 

supervised or instructed in safe use of the ap-

pliance  and  familiarised  with  potential  dan-

gers.

 

WARNING:

  Children  must  not  be  allowed 

to play with the appliance. Store all packaging 

material out of reach of children 

(comes with a 

plastic bag – su

ff

ocation hazard)

.

 

WARNING: 

Cleaning  and  maintenance  of 

the appliance on the part of the user must not 

be done by unsupervised children. 

WARNING:

 Before connecting to main elec-

trical  supply,  check  that  the  voltage  and  fre-

quency in the mains corresponds to the data 

stated on the device.

WARNING:

 Always make sure that the sock-

et you intend to plug the cooler into meets the 

speci

fi

cations on the machine plate (voltage, 

frequency, input power).

WARNING:

  Before  performing  operations 

on the device such as cleaning or maintenance, 

ALWAYS  disconnect  the  device  from  power 

supply: set the thermostat to "O" position and 

unplug the appliance from the socket.  

Содержание GREEN LINE KONTAKT 155

Страница 1: ...LINDR FLOW THROUGH CONTACT COOLER Number 012 2020 REV00 Valid 2020 06 01 INSTRUCTION MANUAL ENGLISH...

Страница 2: ...ins important information necessary to ensure that all operations are done prop erly and safely WARNING Not following instructions may cause injury or damage the device SYMBOLS AND MARKINGS USED IN TH...

Страница 3: ...allation 11 Keg coupler assembly 12 Beverage supply connection and pressurisation 13 Connection and regulation of KONTAKT 155 R 14 How to work with speed fittings 15 Temperature and adjustment 16 Keg...

Страница 4: ...al safety principles Observe the fol lowing safety instructions The supplier is not liable for damage caused by activities carried out on this device without observing the following instructions WARNI...

Страница 5: ...repair WARNING Do not use open flame or po tential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the cool er so that heat created by the cooling unit c...

Страница 6: ...e instruc tion manual or the product s design as defined by the manufacturer Materials replaced dur ing the validity period of the warranty are our property The legitimacy of the warranty claim is alw...

Страница 7: ...fitted onto the bushing and affixed with a clip figure 7 A figure 7 b figure 7 E 1 Turn the compensator lever 1 so that it points down see figure The compensator lever on the tap is used to adjust the...

Страница 8: ...speed fitting onto the keg coupler figure 8 A figure 8 b figure 8 c figure 8 d WARNING Before you screw the speed fitting onto the 5 8 thread make sure the keg coupler air inlet for delivery medium h...

Страница 9: ...ompressor switch 4 Keg coupler A system S system M system 5 F 5 8x9 5 mm speed fitting 6 F 5 8x8 mm speed fitting 7 Beverage 7 4 5 6 1 2 3 12 2 Connection and Pressurisation by CO2 Bottle One Tap Devi...

Страница 10: ...compressor and GREEN LINE models PYG MY 20 K PYGMY 25 K KONTAKT 40 K KONTAKT 70 K KONTAKT 155 K The air mini compressor is built into the cooling device itself Automatic pressure regulation is set to...

Страница 11: ...e figure 11 a Other Pressurisation Options By PUMA 1HP and 1 2HP compressor LEONARDO 1HP compressor AIRCRAFT 1HP compres sor classic Biogon N2 bottles 12 5 Connecting KONTAKT 155 R to Pressurisation w...

Страница 12: ...pressure gauges located on the front of the cooler 7 Tap the keg using the keg coupler WARNING Check that all joints are sufficiently leak tight after connection If everything is in order check the t...

Страница 13: ...olic beverages set the thermostat knob to 5 at the most otherwise there is a risk of the beverage freezing in the cooler s tubing and damaging the device 14 2 Speed Fitting Removal Hold the grey ring...

Страница 14: ...b figure 14 c figure 14 d figure 14 e 16 KEG TAPPING AND UNTAPPING 16 1 Keg Tapping Procedure for tapping a keg using an S system keg coupler WARNING Make sure the adapter is clean before tapping the...

Страница 15: ...tapping a keg using an A system keg coupler A system keg coupler figure 15 d figure 15 e 16 2 Keg Untapping Procedure for untapping a keg using an S system keg coupler figure 15 a figure 15 b figure...

Страница 16: ...WARNING If a leakage is found untap the keg according to point 16 and turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are unsure how to proceed contac...

Страница 17: ...leanliness of condenser plates device overheats place the device in a colder environment tap jerks drink sprays out pressure too high reduce delivery medium supply reduce pressure in the keg air compr...

Страница 18: ...ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufacturer Sanitation Procedure Once you have finished a keg...

Страница 19: ...sier use a sanitation adapter according to your type of keg coupler not included in standard accesso ries The cooler must be sanitised once every 14 days by a person with chemical engineering qualific...

Страница 20: ......