![Lincoln Impinger II - Advantage Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/lincoln/impinger-ii-advantage-series/impinger-ii-advantage-series_service-manual_1917805020.webp)
Impinger II – Advantage Service Manual - Domestic
20
ELECTRONIC TEMPERATURE CONTROL BOARD - REPLACEMENT
1.
Remove control box cover.
2.
Disconnect wires and molded connector and mark for reinstallation.
3.
Depress nylon clips and remove circuit board from mounting bracket.
4.
Reassemble in reverse order and check operation.
ELECTRONIC TEMPERATURE CONTROL BOARD - CALIBRATION
1.
Place the thermocouple of your test meter through a finger hole in the top center of the oven.
2.
With temperature dial fully counter clockwise, align dial red line over "CAL" mark on temperature scale
and tighten dial knob.
3.
Turn temperature dial fully clockwise, adjust pot on temperature control to achieve 575°F on temperature
meter.
4.
Set dial to 500°F. Adjust dial to match actual temperature.
5.
Seal adjustment pot with glyptol or nail polish.
TEMPERATURE CONTROL POTENTIOMETER - REPLACEMENT
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Loosen two (2) allen screws and remove knob by sliding off shaft.
4.
Remove mounting nut from potentiometer shaft and push out.
5.
Unplug wire connector from control board.
6.
Reassemble in reverse order and check system operation.
HEAT LIGHT - REPLACEMENT
1.
Shut off power at main breaker.
2.
Remove control panel top and front panel.
3.
Remove two wires from burner light, note number and location.
4.
Grasp body of light assembly and slide sideways to remove.
5.
Reassemble in reverse order and check.
BURNER CONTROL - HONEYWELL - REPLACEMENT
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Remove wires from control, note wire numbers and location for reassembly.
4.
Remove screws from control and replace.
5.
Reassemble in reverse order and check system operation.
GAS VALVE - REPLACEMENT
1.
Shut off power at main breaker.
2.
Shut off the gas supply in the main line to the oven.
3.
Disconnect the flexible gas hose.
4.
Remove the control panel top and front panel.
5.
Remove the manual gas shut off valve from piping.
6.
Remove screws from the bulkhead plate located on rear of oven at the gas pipe.
7.
Remove the section of gas pipe to gas valve.
8.
Disconnect the electrical leads from the solenoid valve. Disconnect bypass tube.
9.
Loosen the gas line union located near the burner and remove the gas valve and piping assembly.
10.
Finish removal of the gas piping from gas valve.
11.
Reassemble in reverse order.
12.
Check all gas fittings for leaks.
13.
Adjust the gas manifold pressure on the gas valve. "Refer to the specification plate on the oven for
proper rating."
Содержание Impinger II - Advantage Series
Страница 5: ...Impinger II Advantage Service Manual Domestic 5 SCHEMATIC 1116 000 A 1117 000 A...
Страница 6: ...Impinger II Advantage Service Manual Domestic 6 SCHEMATIC 1130 000 A 1131 000 A...
Страница 7: ...Impinger II Advantage Service Manual Domestic 7 SCHEMATIC 1132 000 A 1133 000 A...
Страница 25: ...Impinger II Advantage Service Manual Domestic 25 This page intentionally left blank...
Страница 27: ...Impinger II Advantage Service Manual Domestic 27 BLOW UP GENERAL...
Страница 29: ...Impinger II Advantage Service Manual Domestic 29 BLOW UP CONTROL BOX 1116 000 A 1117 000 A...
Страница 31: ...Impinger II Advantage Service Manual Domestic 31 BLOW UP CONTROL BOX 1130 000 A THRU 1133 000 A...
Страница 33: ...Impinger II Advantage Service Manual Domestic 33 BLOW UP CONVEYOR DOOR...
Страница 35: ...Impinger II Advantage Service Manual Domestic 35 BLOW UP OVEN BACK ASSEMBLY...
Страница 36: ...Impinger II Advantage Service Manual Domestic 36...