![Lincoln Impinger II - Advantage Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/lincoln/impinger-ii-advantage-series/impinger-ii-advantage-series_service-manual_1917805016.webp)
Impinger II – Advantage Service Manual - Domestic
16
Hall Effect Sensor
Check for any physical damage to hall effect sensor
(mounted on conveyor drive motor.) Check all
wiring and connections for damage. check all
connections for damage. Check all connections for
tightness or proper location and check all wiring for
visible damage. Replace as needed . Connect
new hall effect to system and check for steady
operation.
Temp. Display inoperative
Display Transformer
Measure the transformer primary for input, if
voltage is not present, trace wiring back to the oven
power source. Measure the secondary output,
which will normally by 12-15 VAC. Voltage across
terminals 1 and 3 on the time/temp. display should
read 12-15 VAC. Terminals 1-2 and 2-3 should be
1/2 the voltage reading from 1-3. if the above
secondary readings are not achieved, replace
transformer
Temperature Display
If proper voltage is present at terminals 1, 2, and 3
on temperature display, but the display is not
lighted, recheck all connections for tightness.
Temperature display is still not operating, replace
the temperature display.
Temp. Display inaccurate,
erratic or inoperative
Thermocouple
Place the thermocouple of a pyrometer into the
center of the top finger. Be sure the tip of the
thermocouple is not touching metal, it must sense
air temperature only. The pyrometer will indicate
oven temperature.
Measure
DC
millivolts
of thermocouple at the
temperature display. See thermocouple chart on
page 19 for proper readings. Replace
thermocouple if proper readings are not achieved.
If readings are correct on the thermocouple, replace
temperature display.
Содержание Impinger II - Advantage Series
Страница 5: ...Impinger II Advantage Service Manual Domestic 5 SCHEMATIC 1116 000 A 1117 000 A...
Страница 6: ...Impinger II Advantage Service Manual Domestic 6 SCHEMATIC 1130 000 A 1131 000 A...
Страница 7: ...Impinger II Advantage Service Manual Domestic 7 SCHEMATIC 1132 000 A 1133 000 A...
Страница 25: ...Impinger II Advantage Service Manual Domestic 25 This page intentionally left blank...
Страница 27: ...Impinger II Advantage Service Manual Domestic 27 BLOW UP GENERAL...
Страница 29: ...Impinger II Advantage Service Manual Domestic 29 BLOW UP CONTROL BOX 1116 000 A 1117 000 A...
Страница 31: ...Impinger II Advantage Service Manual Domestic 31 BLOW UP CONTROL BOX 1130 000 A THRU 1133 000 A...
Страница 33: ...Impinger II Advantage Service Manual Domestic 33 BLOW UP CONVEYOR DOOR...
Страница 35: ...Impinger II Advantage Service Manual Domestic 35 BLOW UP OVEN BACK ASSEMBLY...
Страница 36: ...Impinger II Advantage Service Manual Domestic 36...