Power Supply
If there is sufficient micro-amp current, but the flame
will not stay lit, check for proper polarity of the 120
VAC power supply.
Ignition Control
If there is sufficient micro-amp current, and the 120
VAC polarity is correct, but the flame will not stay lit,
replace ignition control.
NOTE: Check for proper ground connection on
ignition control.
NOTE: Flame should be lit at
this time.
Low flame is on,
but no main flame
Temperature Control
Check for 120 VAC at terminal #7
to neutral on temperature control. If no voltage,
trace voltage back through centrifugal switch and hi-
limit. Turn the temperature adjustment knob to
maximum temperature position and check for 120
VAC at the load terminal #8 and neutral. If 120 VAC
is present and unit is not heating, refer to
"Temperature Solenoid Valve" for next check. If 120
VAC is not present, proceed.
Thermocouple Probe
WITH POWER ON AND THERMOCOUPLE LEADS
ATTACHED TO THE TEMPERATURE CONTROL
BOARD: Measure the D.C. millivolt output of these
leads. Refer to thermocouple chart in Section D for
proper readings. If these readings are not achieved,
replace the thermocouple.
Temperature Set
Disconnect the potentiometer leads
Potentiometer
from the board. Place ohm meter test leads on the
blue and green pot leads. Reading should be 1 K
ohms. Place meter leads across the blue and purple
pot leads and rotate knob from high to low. Repeat
on green and purple leads. Check for even rise and
fall of ohms reading to insure that there are no open
or dead spots in the potentiometer. Check each
lead to ground for shorts. Replace pot if it does not
meet the above test.
Temperature Solenoid
If 120 VAC is present on the
Valve
temperature control board at load terminal #8 to
neutral, check for voltage at temperature regulation
valve. If voltage is present, listen for valve to open
and close. Also check for opens or shorts in the coil.
Replace as necessary.
Intermittent Heating
Thermal/Overload of Main Fan
and Burner Blower Motors
The main fan motor and the burner blower motor are
equipped with internal thermal protection and will
cease to operate if over heating occurs. As the
motors overheat and then cool, this will cause the
units to cycle on and off intermittently. This may be
caused by improper ventilation or preventive
maintenance. Also, most of the problems listed
under "Oven will not heat" can cause intermittent
failure.
Conveyor will not run
Voltage Supply
Check incoming voltage supply at line 1 to neutral.
There should be a voltage reading of 120 VAC. If
not present, check breakers.
10 Amp Fuse
Check and/or replace.
Fuseholder
Check and/or replace.
Fan Switch
See procedure for checking on Page 10.
Содержание Impinger II - Advantage Series
Страница 5: ...Impinger II Advantage Service Manual Domestic 5 SCHEMATIC 1116 000 A 1117 000 A...
Страница 6: ...Impinger II Advantage Service Manual Domestic 6 SCHEMATIC 1130 000 A 1131 000 A...
Страница 7: ...Impinger II Advantage Service Manual Domestic 7 SCHEMATIC 1132 000 A 1133 000 A...
Страница 25: ...Impinger II Advantage Service Manual Domestic 25 This page intentionally left blank...
Страница 27: ...Impinger II Advantage Service Manual Domestic 27 BLOW UP GENERAL...
Страница 29: ...Impinger II Advantage Service Manual Domestic 29 BLOW UP CONTROL BOX 1116 000 A 1117 000 A...
Страница 31: ...Impinger II Advantage Service Manual Domestic 31 BLOW UP CONTROL BOX 1130 000 A THRU 1133 000 A...
Страница 33: ...Impinger II Advantage Service Manual Domestic 33 BLOW UP CONVEYOR DOOR...
Страница 35: ...Impinger II Advantage Service Manual Domestic 35 BLOW UP OVEN BACK ASSEMBLY...
Страница 36: ...Impinger II Advantage Service Manual Domestic 36...