SPACING 

 

The oven must have 6 inches (152 mm) of clearance from combustible surfaces.  In case other equipment is 

located on the right side of oven, a minimum clearance of 24 inches (609 mm) is required from that equipment. 

 

FOR ALL OVENS: A 24-inch (609 mm) clearance at the rear of the oven must be obtainable for service access.  

FOR IMPINGER

®

 II OVENS: A permanently installed (unmovable) oven requires a minimum of 4 feet clearance on 

the right hand side to allow for conveyor removal, cleaning, and servicing.   

 

NOTE: Do not install this (these) oven(s) in any area with an ambient temperature in excess of 95° F / 35° C.  

Doing so will cause damage to the unit. 

 

 

 

 

 

VENTILATION 

 

A VENT IS REQUIRED: Local codes prevail.  These are the “authority having jurisdiction” as stated by the 

NATIONAL FIRE PROTECTION ASSOCIATION, INC. in NFPA 96 latest edition.  In addition, to be in compliance 

with the NFPA 54 Section 10.3.5.2, this unit must be installed with a ventilation hood interlock that prevents the unit 

from operating when the ventilation hood is off. For further ventilation information, see below. 

 

 

VENTILATION GUIDELINES 

 

A ventilation hood is required to remove heat and cooking odors.  For gas ovens, a ventilation hood is also required 

to remove the products of combustion.  The hood and HVAC installation must meet local codes to gain approval by 

the authority having jurisdiction.  Requirements may vary throughout the country depending on the location by city, 

county, and state.  Obtain information from the authority having jurisdiction to determine the requirements for your 

installation.  Obtain information and review copies of codes or documents that will be used to inspect and approve 

your installation.  Your ventilation hood supplier and HVAC contractor should be contacted to provide guidance.  A 

properly engineered and installed ventilation hood and HVAC system will expedite approval and reduce oven 

maintenance costs.  Proper ventilation is the oven owner’s responsibility. 

 

The ventilation hood must operate in harmony with the building HVAC system.  It typically requires between 750 

and 2500 CFM exhaust.  (The “Efficiency” of various hood designs makes it necessary to specify such a wide range 

of ventilator CFM.)  Make up air must be supplied by either a hood design or the HVAC system.  This will vary with 

hoods from various manufacturers. 

 

CAUTION: Prevent airflow through the cooking tunnel.  Air must NOT be directed onto the oven front or at 

side of cooking area or rear of oven. 

 

Performance will be evaluated during Start-up Checkout by conducting a smoke candle test.  The hood must 

capture all smoke from the oven.  This is required to assure proper performance of the oven and to eliminate 

additional service calls that occur when ambient temperatures are too high.  In all cases, the ambient temperature 

around the oven must be less than 95° F / 35° C when the oven is operating.  In certain localities, other chemical or 

gaseous methods of detecting adequate capture will be the requirement to meet the local code authority. 

 

The drawing shown on page 7 is a typical installation and is intended to be a guideline.  It is not a rigid 

specification.  Hood dimensions and the positioning of the hood over the oven will vary with hood manufacturers. 

 

NOTE: Lincoln can provide oven spec sheets that show the dimensions of the oven, KW or BTU ratings and other 

information that will be useful to both the ventilation hood supplier and the HVAC contractor. 

 

IN AUSTRALIA:

  Refer to Standard AS 5601.  This standard specifies the requirements for piping, flueing, 

ventilation and appliance installation associated with use of or intended use of fuel gases.  The requirements of AS 

5601 are to be used in conjunction with, but do not take precedence over, any statutory regulations that may apply 

in any area. 

!

 

CAUTION:

 

Oven must be operated on approved basis only. 

Содержание Impinger II 1116

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS for IMPINGER II CONVEYOR OVENS ADVANTAGE CONVEYOR OVENS MODEL SERIES 1100 TO BE SERVICED ONLY BY AUTHORIZED PERSONS 1100opsman REV 4 3 07 Part Number 2810075...

Страница 2: ...KOUT must occur within 24 months of manufacturing date for warranty to be in effect For ovens installed in locations other than the United States or Canada defective parts of the original equipment ar...

Страница 3: ...on site Please note the specific details on the Warranty and make certain that service connections are made to proper utility services The warranty shall not apply if the oven s are started up and op...

Страница 4: ...as 40 000 BTU 120 VAC 7 Amps 1 60 Hz 3 Wires 1 Pole N G 1 Pole 15 Amp 40 000 BTU at 7 inches H2O column CSA NSF 1117 L P Gas 40 000 BTU 120 VAC 7 Amps 1 60 Hz 3 Wires 1 Pole N G 1 Pole 15 Amp 40 000 B...

Страница 5: ...enmark Danish J 9 Belgium Dutch French K 10 Netherlands Dutch L 11 Ireland English F 12 Greece Greek M 13 Austria German C 14 Finland Finnish N 15 Norway Norwegian P 16 Sweden Swedish R EXAMPLE 1433 B...

Страница 6: ...ly engineered and installed ventilation hood and HVAC system will expedite approval and reduce oven maintenance costs Proper ventilation is the oven owner s responsibility The ventilation hood must op...

Страница 7: ...ralia an alternate method of coloring the air may be used 1 Wear heat resistant gloves to prevent burns to your hands 2 Put the smoke candle in a cake pan approximately 8 inches 200 mm x 8 inches 200...

Страница 8: ...exible stainless steel belt travel distances of 52 inches 1320 mm with 24 inches 610 mm in the baking area Conveyor belt width is 18 inches 460 mm Speed range 50 seconds 30 minutes DB LEVEL 70dba OPER...

Страница 9: ...xible stainless steel belt travel distances of 52 inches 1320 mm with 24 inches 610 mm in the baking area Conveyor belt width is 18 inches 460 mm Speed range 50 seconds 30 minutes DB LEVEL 70dba OPERA...

Страница 10: ...uel Gas Codes ANSI Z223 1 NFPA 54 latest version Manufacturers Installation Instructions and local municipal building codes ISO 203 1 1 The oven and its individual shut off valve must be disconnected...

Страница 11: ...s should be close together RESTRAINT REQUIREMENT Gas Oven s on Casters 1 The installation shall be made with a gas connector that complies with the local codes for Connectors for Movable Gas Appliance...

Страница 12: ...ll uncrated components of the Impinger Conveyor Oven will pass through a 30 inch wide door The Impinger Conveyor Oven consists of Cartons or Crates Weight of Each Dimensions of Each 1 oven export 486...

Страница 13: ...p in place and save 2 in front 2 in rear FOR DOUBLE OVEN Step 2 FOR DOUBLE OVEN Step 3 TOP UNIT 1 Remove door conveyor and finger assemblies 2 Turn unit on left side as shown 3 Drill holes in cover as...

Страница 14: ...in front and 2 screws in back Save the screws 3 Replace door conveyor and fingers 1 Prepare top for mounting as shown above OVEN TO BE STACKED 1 Remove door conveyor and finger assemblies 2 Turn unit...

Страница 15: ...coupling firmly and pull toward conveyor 4 Coupling will snap back allowing removal of conveyor Set screw on conveyor side is a spring loaded ball detent and is NOT to be tightened firmly 5 Proceed t...

Страница 16: ...that is too tight will impede the smooth operation of the conveyor FINGER ASSEMBLY REMOVAL DISASSEMBLY The Connecting Links may be removed with a pair of pliers by slipping the eye of the connecting...

Страница 17: ...re you call the Authorized Service Agency The name and phone number of the Authorized Service Agency should be located on the oven or contact the factory for the name of the nearest Authorized Service...

Страница 18: ...Impinger II Digital Advantage Ops Manual Dom Int l 18...

Страница 19: ...N CONVEYOR and HEAT to ON The electric oven should come on immediately The gas oven should light in 45 50 seconds 2 GAS OVENS ONLY If the indicator lamp does not light turn HEAT switch off wait 5 minu...

Страница 20: ...on to jump over to that mode DIAGNOSTIC MESSAGES The Digital Advantage ovens have diagnostic messages within the control Upon the unexpected event that there is a failure in the oven operation the fol...

Страница 21: ...ean exterior surfaces of the oven by wiping it down with a mild detergent and clean water or a commercial stainless cleaner 2 Clean crumb pans and guards by washing with a mild detergent solution and...

Страница 22: ...Impinger II Digital Advantage Ops Manual Dom Int l 22 APPENDIX A LABEL DEFINITIONS...

Страница 23: ...ir encircling the product and heats the food more efficiently because the air concentrates heat on the product Greater heat transfer rates which result in products baking two or four times faster than...

Страница 24: ...cies throughout the world Those agencies employ nearly 1 200 service representatives The end result a cohesive international network designed to serve every need of the professional foodservice operat...

Отзывы: