UTILITY SPECIFICATIONS REQUIRED – ELECTRIC 

Model 

Energy 

Power 

Voltage 

Current 

Phase 

Hz 

Recommended 

Electrical Specification 

Recommended 

Circuit Breaker 

Supply Wire 

Size 90° C 

Agency Listings 

1130/60 

Electric 

10kW 

120/208 VAC 

48 Amps 

60 Hz 

4 Wires, 2 Pole + N + G 

2 Pole, 50 Amp 

6 AWG 

UL, CSA, NSF 

1131/61 

Electric 

10kW 

120/240 VAC 

42 Amps 

60 Hz 

4 Wires, 2 Pole + N + G 

2 Pole, 50 Amp 

8 AWG 

UL, CSA, NSF 

1132/62 

Electric 

10kW 

120/208 VAC 

28 Amps 

60 Hz 

5 Wires, 3 Pole + N + G 

3 Pole, 30 Amp 

10 AWG 

UL, CSA, NSF 

1133/63 

Electric 

10kW 

120/240 VAC 

25 Amps 

60 Hz 

5 Wires, 3 Pole + N + G 

3 Pole, 30 Amp 

10 AWG 

UL, CSA, NSF 

1130-080-A 

Electric 

10kW 

120/208 VAC 

48 Amps 

60 Hz 

4 Wires, 2 Pole + N + G 

2 Pole, 50 Amp 

6 AWG 

UL, CSA, NSF 

1131/61-080-A 

Electric 

10kW 

120/240 VAC 

42 Amps 

60 Hz 

4 Wires, 2 Pole + N + G 

2 Pole, 50 Amp 

8 AWG 

UL, CSA, NSF 

1132/62-080-A 

Electric 

10kW 

120/208 VAC 

28 Amps 

60 Hz 

5 Wires, 3 Pole + N + G 

3 Pole, 30 Amp 

10 AWG 

UL, CSA, NSF 

1133-080-A 

Electric 

10kW 

120/240 VAC 

25 Amps 

60 Hz 

5 Wires, 3 Pole + N + G 

3 Pole, 30 Amp 

10 AWG 

UL, CSA, NSF 

1134 

Electric 

10kW 

380Y/208 VAC 

15 Amps 

50 Hz 

5 Wires, 3 Pole + N + G 

 

5 x 2.5mm

2

 

NSF 

1135 

Electric 

10kW 

415Y/240 VAC 

14 Amps 

50 Hz 

5 Wires, 3 Pole + N + G 

 

5 x 2.5mm

2

 

NSF 

1136 

Electric 

10kW 

240 VAC 

42 Amps 

50 Hz 

3 Wires, 1 Pole + N + G 

 

3 x 10.0mm

2

 

NSF 

1151 

Electric 

10kW 

200VAC 

29 Amps 

60 Hz 

4 Wires, 3 Pole + G 

 

3 x 4.0mm

2

 

NSF 

*1164-XXX-E 

Electric 

10kW 

400/230 VAC 

15 Amps 

50 Hz 

5 Wires, 3 Pole + N + G 

3 Pole, 32 Amp 

5 x 2.5mm

2

 

CE, NSF 

1130-000-A 

Electric 

10kW 

208 VAC 

48 Amps 

60 Hz 

3 Wires, 2 Pole + G 

2 Pole, 50 Amp 

6 AWG 

UL, CSA, NSF 

1131-000-A 

Electric 

10kW 

240 VAC 

42 Amps 

60 Hz 

3 Wires, 2 Pole + G 

2 Pole, 50 Amp 

8 AWG 

UL, CSA, NSF 

1132-000-A 

Electric 

10kW 

208 VAC 

28 Amps 

60 Hz 

4 Wires, 3 Pole + G 

3 Pole, 30 Amp 

10 AWG 

UL, CSA, NSF 

1133-000-A 

Electric 

10kW 

240 VAC 

25 Amps 

60 Hz 

4 Wires, 3 Pole + G 

3 Pole, 30 Amp 

10 AWG 

UL, CSA, NSF 

1130-08H-A 

Electric 

12kW 

208 VAC 

63 Amps 

60 Hz 

3 Wires, 2 Pole + G 

2 Pole, 90 Amp 

4 AWG 

UL, cUL, NSF 

1131-08H-A 

Electric 

12kW 

240 VAC 

54 Amps 

60 Hz 

3 Wires, 2 Pole + G 

2 Pole, 50 Amp 

6 AWG 

UL, cUL, NSF 

1132-08H-A 

Electric 

12kW 

208 VAC 

36 Amps 

60 Hz 

4 Wires, 3 Pole + G 

3 Pole, 70 Amp 

8 AWG 

UL, cUL, NSF 

1133-08H-A 

Electric 

12kW 

240 VAC 

31 Amps 

60 Hz 

4 Wires, 3 Pole + G 

3 Pole, 40 Amp 

10 AWG 

UL, cUL, NSF 

 

* REF MODEL NUMBER KEY 

UTILITY SPECIFICATIONS REQUIRED – GAS 

Model 

Energy 

Power 

Voltage 

Current 

Phase 

Hz 

Recommended 

Electrical Specification 

Recommended 

Circuit Breaker 

Gas 

Agency Listings 

1116 

Nat. Gas 

40,000 BTU 

120 VAC 

7 Amps 

60 Hz 

3 Wires, 1 Pole + N + G 

1 Pole, 15 Amp 

40,000 BTU at 7 inches, H

2

O column** 

CSA, NSF 

1117 

L.P. Gas 

40,000 BTU 

120 VAC 

7 Amps 

60 Hz 

3 Wires, 1 Pole + N + G 

1 Pole, 15 Amp 

40,000 BTU at 11 inches, H

2

O column** 

CSA, NSF 

1154 

Nat. Gas 

45 MJ 

240 VAC 

2 Amps 

50 Hz 

3 Wires, 1 Pole + N + G 

 

45 MJ/HR at 1.7 kPa, H

2

O column** 

AGA*, NSF 

1155 

L.P. Gas 

45 MJ 

240 VAC 

2 Amps 

50 Hz 

3 Wires, 1 Pole + N + G 

 

45 MJ/HR at 2.73 kPa, H

2

O column** 

AGA*, NSF 

1156 

Town 

45 MJ 

240 VAC 

2 Amps 

50 Hz 

3 Wires, 1 Pole + N + G 

 

45 MJ/HR at 3.6 kPa, H

2

O column** 

AGA*, NSF 

1157 

Nat. Gas 

40,000 BTU 

220/240 VAC 

2 Amps 

50 Hz 

3 Wires, 1 Pole + N + G 

 

40,000 BTU at 7 inches, H

2

O column** 

NSF 

1158 

L.P. Gas 

40,000 BTU 

220/240 VAC 

2 Amps 

50 Hz 

3 Wires, 1 Pole + N + G 

 

40,000 BTU at 11 inches, H

2

O column** 

NSF 

*1154-XXX-E 

Nat. Gas 

12kW 

230 VAC 

2 Amps 

50 Hz 

3 Wires, 1 Pole + N + G 

1 Pole, 16 Amp 

12 kW/HR at 17.4 mB, H

2

O column** 

CE, NSF 

*1155-XXX-E 

L.P. Gas 

12kW 

230 VAC 

2 Amps 

50 Hz 

3 Wires, 1 Pole + N + G 

1 Pole, 16 Amp 

12 kW/HR at 27.4 mB, H

2

O column** 

CE, NSF 

1116-000-A 

Nat. Gas 

40,000 BTU 

120 VAC 

7 Amps 

60 Hz 

3 Wires, 1 Pole + N + G 

1 Pole, 15 Amp 

40,000 BTU at 7 inches, H

2

O column** 

CSA, NSF 

1117-000-A 

L.P. Gas 

40,000 BTU 

120 VAC 

7 Amps 

60 Hz 

3 Wires, 1 Pole + N + G 

1 Pole, 15 Amp 

40,000 BTU at 11 inches, H

2

O column** 

CSA, NSF 

1116-080-A 

Nat. Gas 

40,000 BTU 

120 VAC 

7 Amps 

60 Hz 

3 Wires, 1 Pole + N + G 

1 Pole, 15 Amp 

40,000 BTU at 7 inches, H

2

O column** 

CSA, NSF 

1117-080-A 

L.P. Gas 

40,000 BTU 

120 VAC 

7 Amps 

60 Hz 

3 Wires, 1 Pole + N + G 

1 Pole, 15 Amp 

40,000 BTU at 11 inches, H

2

O column** 

CSA, NSF 

 

GAS PRESSURE CONVERSION CHART 

Inches of 

Water Column 

KPa 

m-Bar 

Millimeters of 

Water Column 

3.5 

0.87 

8.70 

88.9 

4.5 

1.12 

11.2 

114.3 

1.74 

17.40 

177.8 

10 

2.48 

24.87 

254.0 

10.5 

2.61 

26.11 

266.7 

11 

2.73 

27.36 

279.4 

14 

3.48 

34.81 

355.6 

14.5 

3.61 

36.05 

368.3 

* AGA – Australia Gas Association (See 1154 & 1155 above) 

 

** NOTE:  For proper operation, the gas valve requires a nominal inlet pressure of 7 inches of H

2

O for natural gas and 11 inches of H

2

O column 

for L.P. gas.  A minimum inlet pressure of 1.0 inch of H

2

O column above the manifold setting (NAT. manifold 3.5” H

2

O, L.P. manifold 10” H

2

O) 

must be maintained with no pressure drop from the no load to full load condition.  The maximum inlet pressure must be maintained at or below 

½ PSIG (14.5 inches H

2

O column).  Refer to the chart on the left for pressure conversions. 

 

Electrical Supply for Australia: 

Single Phase:  240 VAC, 50 Hz / 20 Amp; one neutral & one earth/ground. 

Three Phase:  240/415 VAC / 20 Amp; three active, one neutral & one earth/ground. 

 

All ovens require separate service and dedicated neutral. 

 

NOTE:  Do not install the (these) oven(s) in any area with an ambient temperature in excess of 95°F / 35° C.  Doing so will cause damage to the 

unit. 

 

Содержание Impinger II 1116

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS for IMPINGER II CONVEYOR OVENS ADVANTAGE CONVEYOR OVENS MODEL SERIES 1100 TO BE SERVICED ONLY BY AUTHORIZED PERSONS 1100opsman REV 4 3 07 Part Number 2810075...

Страница 2: ...KOUT must occur within 24 months of manufacturing date for warranty to be in effect For ovens installed in locations other than the United States or Canada defective parts of the original equipment ar...

Страница 3: ...on site Please note the specific details on the Warranty and make certain that service connections are made to proper utility services The warranty shall not apply if the oven s are started up and op...

Страница 4: ...as 40 000 BTU 120 VAC 7 Amps 1 60 Hz 3 Wires 1 Pole N G 1 Pole 15 Amp 40 000 BTU at 7 inches H2O column CSA NSF 1117 L P Gas 40 000 BTU 120 VAC 7 Amps 1 60 Hz 3 Wires 1 Pole N G 1 Pole 15 Amp 40 000 B...

Страница 5: ...enmark Danish J 9 Belgium Dutch French K 10 Netherlands Dutch L 11 Ireland English F 12 Greece Greek M 13 Austria German C 14 Finland Finnish N 15 Norway Norwegian P 16 Sweden Swedish R EXAMPLE 1433 B...

Страница 6: ...ly engineered and installed ventilation hood and HVAC system will expedite approval and reduce oven maintenance costs Proper ventilation is the oven owner s responsibility The ventilation hood must op...

Страница 7: ...ralia an alternate method of coloring the air may be used 1 Wear heat resistant gloves to prevent burns to your hands 2 Put the smoke candle in a cake pan approximately 8 inches 200 mm x 8 inches 200...

Страница 8: ...exible stainless steel belt travel distances of 52 inches 1320 mm with 24 inches 610 mm in the baking area Conveyor belt width is 18 inches 460 mm Speed range 50 seconds 30 minutes DB LEVEL 70dba OPER...

Страница 9: ...xible stainless steel belt travel distances of 52 inches 1320 mm with 24 inches 610 mm in the baking area Conveyor belt width is 18 inches 460 mm Speed range 50 seconds 30 minutes DB LEVEL 70dba OPERA...

Страница 10: ...uel Gas Codes ANSI Z223 1 NFPA 54 latest version Manufacturers Installation Instructions and local municipal building codes ISO 203 1 1 The oven and its individual shut off valve must be disconnected...

Страница 11: ...s should be close together RESTRAINT REQUIREMENT Gas Oven s on Casters 1 The installation shall be made with a gas connector that complies with the local codes for Connectors for Movable Gas Appliance...

Страница 12: ...ll uncrated components of the Impinger Conveyor Oven will pass through a 30 inch wide door The Impinger Conveyor Oven consists of Cartons or Crates Weight of Each Dimensions of Each 1 oven export 486...

Страница 13: ...p in place and save 2 in front 2 in rear FOR DOUBLE OVEN Step 2 FOR DOUBLE OVEN Step 3 TOP UNIT 1 Remove door conveyor and finger assemblies 2 Turn unit on left side as shown 3 Drill holes in cover as...

Страница 14: ...in front and 2 screws in back Save the screws 3 Replace door conveyor and fingers 1 Prepare top for mounting as shown above OVEN TO BE STACKED 1 Remove door conveyor and finger assemblies 2 Turn unit...

Страница 15: ...coupling firmly and pull toward conveyor 4 Coupling will snap back allowing removal of conveyor Set screw on conveyor side is a spring loaded ball detent and is NOT to be tightened firmly 5 Proceed t...

Страница 16: ...that is too tight will impede the smooth operation of the conveyor FINGER ASSEMBLY REMOVAL DISASSEMBLY The Connecting Links may be removed with a pair of pliers by slipping the eye of the connecting...

Страница 17: ...re you call the Authorized Service Agency The name and phone number of the Authorized Service Agency should be located on the oven or contact the factory for the name of the nearest Authorized Service...

Страница 18: ...Impinger II Digital Advantage Ops Manual Dom Int l 18...

Страница 19: ...N CONVEYOR and HEAT to ON The electric oven should come on immediately The gas oven should light in 45 50 seconds 2 GAS OVENS ONLY If the indicator lamp does not light turn HEAT switch off wait 5 minu...

Страница 20: ...on to jump over to that mode DIAGNOSTIC MESSAGES The Digital Advantage ovens have diagnostic messages within the control Upon the unexpected event that there is a failure in the oven operation the fol...

Страница 21: ...ean exterior surfaces of the oven by wiping it down with a mild detergent and clean water or a commercial stainless cleaner 2 Clean crumb pans and guards by washing with a mild detergent solution and...

Страница 22: ...Impinger II Digital Advantage Ops Manual Dom Int l 22 APPENDIX A LABEL DEFINITIONS...

Страница 23: ...ir encircling the product and heats the food more efficiently because the air concentrates heat on the product Greater heat transfer rates which result in products baking two or four times faster than...

Страница 24: ...cies throughout the world Those agencies employ nearly 1 200 service representatives The end result a cohesive international network designed to serve every need of the professional foodservice operat...

Отзывы: