Lincoln Impinger Conveyor Ovens 1633-000-EA Скачать руководство пользователя страница 9

Low Profile – 1600 Advantage Series Service Manual – International

 

 

 

 

 

 

 

 

 

as needed. 

 

 

 

 

Temperature regulation   

If supply voltage is present on the  

 

 

 

 

valve    

 

 

temperature control board at the load 

 

 

 

 

 

 

 

 

terminals #7 and #8, check for voltage 

 

 

 

 

 

 

 

 

at temperature regulation valve. If  

 

 

 

 

 

 

 

 

voltage is present, listen for valve to  

 

 

 

 

 

 

 

 

open and close. Also, check for opens 

 

 

 

 

 

 

 

 

or shorts in the coil. Replace if required. 

Intermittent heating 

 

Thermal overload of 

 

The main fan motors and the burner  

 

 

 

 

main fan and burner 

 

blower motors are equipped with  

 

 

 

 

blower motors           

 

internal thermal protection and will  

 

 

 

 

 

 

 

 

cease to operate if overheating occurs. 

 

 

 

 

 

 

 

 

As the motors overheat and then cool, 

 

 

 

 

 

 

 

 

this will cause the units to cycle on  

 

 

 

 

 

 

 

 

and off intermittently. This may be  

 

 

 

 

 

 

 

 

caused by improper ventilation or lack 

 

 

 

 

 

 

 

 

of preventive maintenance. Also, most   

 

 

 

 

 

 

 

of the problems listed under “Oven  

 

 

 

 

 

 

 

 

will not heat” can cause intermittent 

 

 

 

 

 

 

 

 

failure. 

Conveyor will not run   

Power supply   

 

Check for supply voltage at terminals 

 

 

 

 

 

 

 

 

L1 and L2. If voltage is not present, 

 

 

 

 

 

 

 

 

check breakers. 

 

 

 

 

Fan switch 

 

 

See procedure for checking on page 6. 

 

 

 

 

Fuse, 10 Amp.   

 

Check and/or replace. 

 

 

 

 

Fuse holder 

 

 

Check and/or replace. 

 

 

 

 

Filter E.M.I. 

 

 

Check for supply voltage input to 

 

 

 

 

 

 

 

 

filter. If there is no voltage, trace wiring  

 

 

 

 

 

 

 

 

back to relay. If there is input voltage,  

 

 

 

 

 

 

 

 

check for output voltage. If there is 

 

 

 

 

 

 

 

 

input voltage but no output voltage, 

 

 

 

 

 

 

 

 

replace filter. 

Speed adjustment  

This is a 0 to 10K ohm, 1 turn  

 

 

 

 

potentiometer    

 

potentiometer. With power off, remove 

 

 

 

 

 

 

 

 

the black and white pot leads from the 

 

 

 

 

 

 

 

 

conveyor control board at terminals 

 

 

 

 

 

 

 

 

P1 and P2. Place the meter leads on  

 

 

 

 

 

 

 

 

black lead (P2) and the white lead (P1). 

 

 

 

 

 

 

 

 

Rotating the pot. slowly, from low to 

 

 

 

 

 

 

 

 

high, the meter reading should show  

 

 

 

 

 

 

 

 

an even transition from 0 to 10K ohms 

 

 

 

 

 

 

 

 

±

 5%. There should be no dead or open 

 

 

 

 

 

 

 

 

spots through the one turn of the pot. 

 

 

 

 

 

 

 

 

Check both leads to ground. There  

 

 

 

 

 

 

 

 

should be no continuity to ground. 

 

 

 

 

 

 

 

 

If any of the above fail, replace  

 

 

 

 

 

 

 

 

the potentiometer. 

 

 

 

 

D.C. motor 

 

 

Check for supply voltage input to 

 

 

 

 

control board    

 

the control board at terminals L1 and L2  

 

 

 

 

 

 

 

If not present, check wiring back to  

 

 

 

 

 

 

 

 

the filter. If supply voltage is present, 

 

 

 

 

 

 

 

 

check both fuses on the control board 

 

 

 

 

 

 

 

 

( 8 Amp. line and 1Amp. armature). 

 

 

 

 

 

 

 

 

Check the D.C. voltage output at  

 

 

 

 

 

 

 

 

terminals A+ and A-. If A.C. voltage 

 

 

 

 

 

 

 

 

is at terminals L1 and L2, and no  

 

 

 

 

 

 

 

 

D.C. voltage is present at A+ and A-, 

 

 

 

 

 

 

replace control board. If A.C. voltage is    

 

 

 

 

 

present and D.C. voltage is present but 

 

 

 

 

 

 

the motor will not run, check gear motor 

 

 

 

 

 

 

as follows: 

 

 

 

 

Conveyor 

 

 

If D.C. voltage is present at A+ and A- 

Содержание Impinger Conveyor Ovens 1633-000-EA

Страница 1: ...ENS LOW PROFILE 1600 INTERNATIONAL ADVANTAGE Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax...

Страница 2: ...E AND PARTS MANUAL 1600 INTERNATIONAL ADVANTAGE SEQUENCE OF OPERATIONS 3 SCHEMATIC 5 TROUBLESHOOTING GUIDE 6 REMOVAL INSTALLATION ADJUSTMENTS 12 GENERAL PARTS 20 ADVANTAGE SERIES 20 CONTROL BOX RIGHT...

Страница 3: ...zes two complete burner temperature control systems The sequence of operations is the same for each system Closing the main fan switch supplies line voltage through the oven power relay through a thre...

Страница 4: ...eyor control uses a sensor and magnet mounted on the conveyor motor that senses motor speed Any change in motor load RPM is detected by the sensor and the voltage to the motor is adjusted accordingly...

Страница 5: ...Low Profile 1600 Advantage Series Service Manual International 5 SCHEMATIC MODELS 1633 000 EA AND 1634 000 EA...

Страница 6: ...insure the contacts are closing Capacitor s Check for opens shorts or grounds Motor s Check for opens shorts or grounds No control box cooling Fan switch SEE OVEN Hi limit FAN WILL Oven fan relay NOT...

Страница 7: ...i limit Ignition control Check for supply voltage to ignition control at terminal 1 and neutral If voltage is not present trace wiring back to hi limit thermostat Check for supply voltage at terminal...

Страница 8: ...rrent but the burner will not remain ignited check the reset button on ignition control NOTE Check for proper polarity of the power supply If all of the above are OK replace ignition control Pilot lam...

Страница 9: ...Check for supply voltage input to filter If there is no voltage trace wiring back to relay If there is input voltage check for output voltage If there is input voltage but no output voltage replace f...

Страница 10: ...eck the speed potentiometer be sure it is OK before changing a control board This test is not always 100 accurate as this test is not performed at operating speeds However this test is the best method...

Страница 11: ...Temperature display Thermocouple Connect the thermocouple of a Inaccurate erratic pyrometer to the thermocouple on Or inoperative the temperature control board be sure to maintain proper polarity of...

Страница 12: ...n reverse order and check system operation AIR PRESSURE SWITCH REPLACEMENT A Remove control panel top B Disconnect wires from switch making note of wire number and location for reinstallation C Remove...

Страница 13: ...or and mark for reassembly E Remove sprocket from motor shaft F Remove 4 screws and remove conveyor motor and mounting bracket G Remove mounting bracket from conveyor motor assembly H Reassemble in re...

Страница 14: ...on bottom of spark generator D Remove 2 mounting screws and remove generator assembly E Reassemble in reverse order and check system operation IGNITER SENSOR REPLACEMENT A Remove appropriate control b...

Страница 15: ...push out C Remove wires from back of switch note wire number and location D Reassemble in reverse order and check system operation NOTE Make sure switch housing is fully seated in control box housing...

Страница 16: ...operation TEMPERATURE SETTING FOR NEW TEMPERATURE CONTROL BOARD PROCEDURE FOR SETTING MAXIMUM TEMPERATURE POTENTIOMETER NOTE When replacing temp control turn oven temperature control to its maximum he...

Страница 17: ...thermocouple from wire form in oven chamber and remove from chamber NOTE R H thermocouple viewed from front is connected directly to the temperature control board remove 2 wires make note of wire colo...

Страница 18: ...0 10 57 11 35 12 89 14 43 15 97 74 F 3 72 5 23 6 76 7 52 8 29 9 83 10 60 11 37 12 92 14 46 15 99 72 F 3 78 5 29 6 82 7 58 8 35 9 89 10 66 11 43 12 97 14 51 16 05 T 70 F 3 83 5 34 6 87 7 63 8 40 9 95 1...

Страница 19: ...Low Profile 1600 Advantage Series Service Manual International 19 This page intentionally left blank...

Страница 20: ...return U L L R S N 35950 Below 370663 Baffle air return U L S N 35951 Above U 370166 Baffle air return U R L L S N 35950 Below 370662 Baffle air return U R S N 35951 Above V 370168 Finger housing T 1...

Страница 21: ...Low Profile 1600 Advantage Series Service Manual International 21...

Страница 22: ...Air pressure switch P 369154 Circuit breaker 7A Q 369192 Capacitor R 357107 Fuse holder S 369013 Fuse 3A 369014 Fuse 10A T 369507 Thermostat cooling fan U 369431 Thermostat control box hi limit V 3701...

Страница 23: ...Low Profile 1600 Advantage Series Service Manual International 23...

Страница 24: ...se 10A H 369368 Thermostat hi limit I 369378 cooling fan J 369192 Capacitor K 370296 Wire hanger L 369575 Air pressure switch M 369025 Air pressure switch N 369580 Gas valve O 369571 Connector P 36958...

Страница 25: ...Low Profile 1600 Advantage Series Service Manual International 25...

Страница 26: ...ockwise rotation C 369776 Fan shroud D 369777 Stand off E 369778 Rear wall assy F 369761 Motor mount G 369759 Motor main fan 220 240V 50 Hz H 1627 Duct cap I 369033 Motor clamp J 370245 Rear duct K 37...

Страница 27: ...Low Profile 1600 Advantage Series Service Manual International 27...

Страница 28: ...mplete conveyor A 369816 Conveyor belting B 369825 Belt 1ft section C 369813 Conveyor bearing block D 369314 Roll conveyor notched E 369812 Conveyor idler shaft F 369160 Conveyor pan stop G 369814 Con...

Страница 29: ...Low Profile 1600 Advantage Series Service Manual International 29...

Страница 30: ...Low Profile 1600 Advantage Series Service Manual International 30 This page intentionally left blank...

Страница 31: ...Low Profile 1600 Advantage Series Service Manual International 31 This page intentionally left blank...

Страница 32: ...Low Profile 1600 Advantage Series Service Manual International 32...

Отзывы: