Lincoln Impinger Conveyor Ovens 1633-000-EA Скачать руководство пользователя страница 6

Low Profile – 1600 Advantage Series Service Manual – International 

TROUBLESHOOTING GUIDE 

                                 MODEL 1633-000 EA   NATURAL GAS   230 VAC   50 HZ   1 PHASE 

                                 MODEL 1634-000-EA   L.P. GAS               230 VAC   50 HZ   1 PHASE 

 

 

NOTE: When checking components on left side of unit, be sure to check for proper 

connections in power connector, ( marked P. C. on schematic diagram ) located inside 

motor cover.  

 

SYMPTOM     

 

POSSIBLE CAUSE   

 

 

EVALUATION 

 

Oven fan will   

 

Incoming power supply   

Check breakers/ reset if required 

not run   

 

 

 

 

 

 

call Power company if needed 

 

 

 

 

Oven fan switch  

 

Check continuity between 

 

 

 

 

 

 

 

 

switch terminals. 

 

 

 

 

Thermostat, hi-limit 

 

Terminals are normally closed, if 

 

 

 

 

 

 

 

 

open, reset thermostat and test 

 

 

 

 

 

 

 

 

oven for proper operation. If it 

 

 

 

 

 

 

 

 

will not reset, replace thermostat. 

 

 

 

 

Fan fuse 

 

 

 

Check, replace if necessary. 

 

 

 

 

Fuse holder 

 

 

Check, replace if necessary. 

 

 

 

 

Oven fan relay   

 

Check for power to coil of oven 

 

 

 

 

 

 

 

 

fan relay. If no voltage is present, 

 

 

 

 

 

 

 

 

trace wiring back to hi-limit thermostat. 

 

 

 

 

 

 

 

 

Check for supply voltage at terminal 

 

 

 

 

 

 

 

 

#6 of the relay. If no voltage is present, 

 

 

 

 

 

 

 

 

trace wiring back to fuse holder. If  

 

 

 

 

 

 

 

 

voltage is present, at the relay coil, check  

 

 

 

 

 

 

 

 

to insure the contacts are closing. 

 

 

 

 

Capacitor(s) 

 

 

Check for opens, shorts, or grounds. 

 

 

 

 

Motor (s)    

 

 

Check for opens, shorts, or grounds. 

No control box cooling   

Fan switch 

 

 

(SEE OVEN 

 

 

 

 

Hi-limit   

 

 

  FAN WILL  

 

 

 

 

Oven fan relay   

 

NOT RUN.) 

 

 

 

 

Cooling fan(s)   

 

Supply voltage should now be at these 

 

 

 

 

 

 

 

 

motors. If voltage is present, check 

 

 

 

 

 

 

 

 

motor for open, shorts, or grounds. 

 

 

 

 

 

 

 

 

WITH POWER OFF: check for 

 

 

 

 

 

 

 

 

locked rotor. 

No automatic control 

 

Incoming power supply   

Check circuit breakers, reset if needed. 

box cooling 

 

 

 

 

 

 

Call power company if needed. 

 

 

 

 

Cooling fan thermostats  

Thermostat closes at 120

°

F and 

 

 

 

 

 

 

 

 

opens at 100

°

F. With the cooling  

 

 

 

 

 

 

 

 

fan thermostat preheated, check 

 

 

 

 

 

 

 

 

for continuity. If switch is open, replace. 

 

 

 

 

Cooling fan(s)   

 

Supply voltage should now be at these 

 

 

 

 

 

 

 

 

motors. If voltage is present, check 

 

 

 

 

 

 

 

 

motor for opens, shorts or grounds. 

 

 

 

 

 

 

 

 

WITH POWER OFF: Check for  

 

 

 

 

 

 

 

 

locked rotor. 

 

Oven will not heat 

 

Gas supply 

 

 

Check for adequate gas supply to oven. 

 

 

 

 

Manual gas shut off valve 

 

Check to see that the manual gas shut 

 

 

 

 

 

 

 

 

off  valve is open. 

 

 

 

 

Fan switch 

 

 

Check to see that the fan switch is on. 

 

 

 

 

Main oven fan   

 

Check if main oven fan is operating. 

 

 

 

 

 

 

 

 

if not, refer to “oven fan will not run”. 

           NOTE: These ovens utilize 2 complete Burner/Temperature control systems. Each system will 

           Follow the same troubleshooting sequence.  

 

 

 

 

Fuse, burner 3A. 

 

 

Check, replace if necessary. 

Содержание Impinger Conveyor Ovens 1633-000-EA

Страница 1: ...ENS LOW PROFILE 1600 INTERNATIONAL ADVANTAGE Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax...

Страница 2: ...E AND PARTS MANUAL 1600 INTERNATIONAL ADVANTAGE SEQUENCE OF OPERATIONS 3 SCHEMATIC 5 TROUBLESHOOTING GUIDE 6 REMOVAL INSTALLATION ADJUSTMENTS 12 GENERAL PARTS 20 ADVANTAGE SERIES 20 CONTROL BOX RIGHT...

Страница 3: ...zes two complete burner temperature control systems The sequence of operations is the same for each system Closing the main fan switch supplies line voltage through the oven power relay through a thre...

Страница 4: ...eyor control uses a sensor and magnet mounted on the conveyor motor that senses motor speed Any change in motor load RPM is detected by the sensor and the voltage to the motor is adjusted accordingly...

Страница 5: ...Low Profile 1600 Advantage Series Service Manual International 5 SCHEMATIC MODELS 1633 000 EA AND 1634 000 EA...

Страница 6: ...insure the contacts are closing Capacitor s Check for opens shorts or grounds Motor s Check for opens shorts or grounds No control box cooling Fan switch SEE OVEN Hi limit FAN WILL Oven fan relay NOT...

Страница 7: ...i limit Ignition control Check for supply voltage to ignition control at terminal 1 and neutral If voltage is not present trace wiring back to hi limit thermostat Check for supply voltage at terminal...

Страница 8: ...rrent but the burner will not remain ignited check the reset button on ignition control NOTE Check for proper polarity of the power supply If all of the above are OK replace ignition control Pilot lam...

Страница 9: ...Check for supply voltage input to filter If there is no voltage trace wiring back to relay If there is input voltage check for output voltage If there is input voltage but no output voltage replace f...

Страница 10: ...eck the speed potentiometer be sure it is OK before changing a control board This test is not always 100 accurate as this test is not performed at operating speeds However this test is the best method...

Страница 11: ...Temperature display Thermocouple Connect the thermocouple of a Inaccurate erratic pyrometer to the thermocouple on Or inoperative the temperature control board be sure to maintain proper polarity of...

Страница 12: ...n reverse order and check system operation AIR PRESSURE SWITCH REPLACEMENT A Remove control panel top B Disconnect wires from switch making note of wire number and location for reinstallation C Remove...

Страница 13: ...or and mark for reassembly E Remove sprocket from motor shaft F Remove 4 screws and remove conveyor motor and mounting bracket G Remove mounting bracket from conveyor motor assembly H Reassemble in re...

Страница 14: ...on bottom of spark generator D Remove 2 mounting screws and remove generator assembly E Reassemble in reverse order and check system operation IGNITER SENSOR REPLACEMENT A Remove appropriate control b...

Страница 15: ...push out C Remove wires from back of switch note wire number and location D Reassemble in reverse order and check system operation NOTE Make sure switch housing is fully seated in control box housing...

Страница 16: ...operation TEMPERATURE SETTING FOR NEW TEMPERATURE CONTROL BOARD PROCEDURE FOR SETTING MAXIMUM TEMPERATURE POTENTIOMETER NOTE When replacing temp control turn oven temperature control to its maximum he...

Страница 17: ...thermocouple from wire form in oven chamber and remove from chamber NOTE R H thermocouple viewed from front is connected directly to the temperature control board remove 2 wires make note of wire colo...

Страница 18: ...0 10 57 11 35 12 89 14 43 15 97 74 F 3 72 5 23 6 76 7 52 8 29 9 83 10 60 11 37 12 92 14 46 15 99 72 F 3 78 5 29 6 82 7 58 8 35 9 89 10 66 11 43 12 97 14 51 16 05 T 70 F 3 83 5 34 6 87 7 63 8 40 9 95 1...

Страница 19: ...Low Profile 1600 Advantage Series Service Manual International 19 This page intentionally left blank...

Страница 20: ...return U L L R S N 35950 Below 370663 Baffle air return U L S N 35951 Above U 370166 Baffle air return U R L L S N 35950 Below 370662 Baffle air return U R S N 35951 Above V 370168 Finger housing T 1...

Страница 21: ...Low Profile 1600 Advantage Series Service Manual International 21...

Страница 22: ...Air pressure switch P 369154 Circuit breaker 7A Q 369192 Capacitor R 357107 Fuse holder S 369013 Fuse 3A 369014 Fuse 10A T 369507 Thermostat cooling fan U 369431 Thermostat control box hi limit V 3701...

Страница 23: ...Low Profile 1600 Advantage Series Service Manual International 23...

Страница 24: ...se 10A H 369368 Thermostat hi limit I 369378 cooling fan J 369192 Capacitor K 370296 Wire hanger L 369575 Air pressure switch M 369025 Air pressure switch N 369580 Gas valve O 369571 Connector P 36958...

Страница 25: ...Low Profile 1600 Advantage Series Service Manual International 25...

Страница 26: ...ockwise rotation C 369776 Fan shroud D 369777 Stand off E 369778 Rear wall assy F 369761 Motor mount G 369759 Motor main fan 220 240V 50 Hz H 1627 Duct cap I 369033 Motor clamp J 370245 Rear duct K 37...

Страница 27: ...Low Profile 1600 Advantage Series Service Manual International 27...

Страница 28: ...mplete conveyor A 369816 Conveyor belting B 369825 Belt 1ft section C 369813 Conveyor bearing block D 369314 Roll conveyor notched E 369812 Conveyor idler shaft F 369160 Conveyor pan stop G 369814 Con...

Страница 29: ...Low Profile 1600 Advantage Series Service Manual International 29...

Страница 30: ...Low Profile 1600 Advantage Series Service Manual International 30 This page intentionally left blank...

Страница 31: ...Low Profile 1600 Advantage Series Service Manual International 31 This page intentionally left blank...

Страница 32: ...Low Profile 1600 Advantage Series Service Manual International 32...

Отзывы: