Low Profile – 1600 Advantage Series Service Manual – International 

 

 

 

 

 

 

 

 

replace the spark generator. If there  

 

 

 

 

 

 

 

 

is visible damage to the igniter/sensor  

 

 

 

 

 

 

 

 

assembly, replace. Also check for frayed 

 

 

 

 

 

 

 

 

or damaged wires in burner tube. 

 

 

 

 

Gas valve 

 

 

Check for supply voltage to gas valve. 

 

 

 

 

 

 

 

 

If there is no voltage present, check  

 

 

 

 

 

 

 

 

reset button, check all connections for 

 

 

 

 

 

 

 

 

tightness. If there still is no voltage at 

 

 

 

 

 

 

 

 

gas valve, replace ignition control. 

 

 

 

 

 

 

 

 

If there is voltage present, check for  

 

 

 

 

 

 

 

 

gas pressure at gas pressure tap located 

 

 

 

 

 

 

 

 

in gas piping at burner manifold. 

 

 

 

 

 

 

 

 

If there is no gas pressure, replace 

 

 

 

 

 

 

 

 

gas valve. 

Flame will not stay on   

Flame sensor   

 

To check for flame sensor operation, 

 

 

 

 

 

 

 

 

connect a digital multimeter (capable 

 

 

 

 

 

 

 

 

of measuring D.C. micro amps) in 

 

 

 

 

 

 

 

 

series with the flame sensor wire and 

 

 

 

 

 

 

 

 

ignition control. Sensor current is 3  

 

 

 

 

 

 

 

 

micro amps D.C. minimum.  

 

 

 

 

 

 

 

 

NOTE: The D.C. micro amp test must 

 

 

 

 

 

 

 

 

be conducted with the oven in low  

 

 

 

 

 

 

 

 

flame (bypass) operation. Turn the  

 

 

 

 

 

 

 

 

temperature control to its lowest  

 

 

 

 

 

 

 

 

setting. If these readings are not 

 

 

 

 

 

 

 

 

achieved, replace igniter/sensor assy. 

 

 

 

 

 

 

 

 

Also, check for any type of damage to 

 

 

 

 

 

 

 

 

flame sensor wire and connections. 

 

 

 

 

Ignition control   

 

If there is sufficient flame sensor current, 

 

 

 

 

 

 

 

 

but the burner will not remain ignited, 

 

 

 

 

 

 

 

 

check the reset button on ignition control. 

 

 

 

 

 

 

 

 

NOTE: Check for proper polarity of 

 

 

 

 

 

 

 

 

the power supply. If all of the above  

 

 

 

 

 

 

 

 

are OK, replace ignition control.  

Pilot lamp is on,  

 

Temperature control 

 

Check for supply voltage across 

But no main flame 

 

 

 

 

 

terminals L2 and 240 on temperature 

 

 

 

 

 

 

 

 

control board. If no voltage is present, 

 

 

 

 

 

 

 

 

check wiring back to hi-limit thermostat. 

 

 

 

 

 

 

 

 

Turn the temperature adjustment knob to 

 

 

 

 

 

 

 

 

the maximum temperature position and 

 

 

 

 

 

 

 

 

check for supply voltage at the load  

 

 

 

 

 

 

 

 

terminal #7 and #8. If voltage is present 

 

 

 

 

 

 

 

 

and unit is not heating, refer to  

 

 

 

 

 

 

 

 

“temperature regulation valve” for next 

 

 

 

 

 

 

 

 

check. If voltage is not present, proceed. 

 

 

 

 

Thermocouple probe 

 

With power on and thermocouple leads 

 

 

 

 

 

 

 

 

attached to board, measure the millivolt 

 

 

 

 

 

 

 

 

out put of the thermocouple. Refer to the 

 

 

 

 

 

 

 

 

thermocouple chart in section D for  

 

 

 

 

 

 

 

 

proper readings. 

 

 

 

 

Temperature control 

 

WITH POWER OFF: Remove the   

 

 

 

 

Potentiometer    

 

potentiometer leads from the temperature 

 

 

 

 

 

 

 

 

control board. Place ohm meter test leads 

 

 

 

 

 

 

 

 

on the blue and green pot leads. Reading  

 

 

 

 

 

 

 

 

should be 1 K ohms. Place meter leads  

 

 

 

 

 

 

 

 

across the blue and purple pot leads and 

 

 

 

 

 

 

 

 

rotate knob from high to low. Repeat on  

 

 

 

 

 

 

 

 

green and purple leads. Check for even  

 

 

 

 

 

 

 

 

rise and fall of ohms reading to insure  

 

 

 

 

 

 

 

 

that there are no open or dead spots in  

 

 

 

 

 

 

 

 

the potentiometer. Check each lead to  

 

 

 

 

 

 

 

 

ground for shorts. Replace potentiometer 

Содержание Impinger Conveyor Ovens 1633-000-EA

Страница 1: ...ENS LOW PROFILE 1600 INTERNATIONAL ADVANTAGE Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax...

Страница 2: ...E AND PARTS MANUAL 1600 INTERNATIONAL ADVANTAGE SEQUENCE OF OPERATIONS 3 SCHEMATIC 5 TROUBLESHOOTING GUIDE 6 REMOVAL INSTALLATION ADJUSTMENTS 12 GENERAL PARTS 20 ADVANTAGE SERIES 20 CONTROL BOX RIGHT...

Страница 3: ...zes two complete burner temperature control systems The sequence of operations is the same for each system Closing the main fan switch supplies line voltage through the oven power relay through a thre...

Страница 4: ...eyor control uses a sensor and magnet mounted on the conveyor motor that senses motor speed Any change in motor load RPM is detected by the sensor and the voltage to the motor is adjusted accordingly...

Страница 5: ...Low Profile 1600 Advantage Series Service Manual International 5 SCHEMATIC MODELS 1633 000 EA AND 1634 000 EA...

Страница 6: ...insure the contacts are closing Capacitor s Check for opens shorts or grounds Motor s Check for opens shorts or grounds No control box cooling Fan switch SEE OVEN Hi limit FAN WILL Oven fan relay NOT...

Страница 7: ...i limit Ignition control Check for supply voltage to ignition control at terminal 1 and neutral If voltage is not present trace wiring back to hi limit thermostat Check for supply voltage at terminal...

Страница 8: ...rrent but the burner will not remain ignited check the reset button on ignition control NOTE Check for proper polarity of the power supply If all of the above are OK replace ignition control Pilot lam...

Страница 9: ...Check for supply voltage input to filter If there is no voltage trace wiring back to relay If there is input voltage check for output voltage If there is input voltage but no output voltage replace f...

Страница 10: ...eck the speed potentiometer be sure it is OK before changing a control board This test is not always 100 accurate as this test is not performed at operating speeds However this test is the best method...

Страница 11: ...Temperature display Thermocouple Connect the thermocouple of a Inaccurate erratic pyrometer to the thermocouple on Or inoperative the temperature control board be sure to maintain proper polarity of...

Страница 12: ...n reverse order and check system operation AIR PRESSURE SWITCH REPLACEMENT A Remove control panel top B Disconnect wires from switch making note of wire number and location for reinstallation C Remove...

Страница 13: ...or and mark for reassembly E Remove sprocket from motor shaft F Remove 4 screws and remove conveyor motor and mounting bracket G Remove mounting bracket from conveyor motor assembly H Reassemble in re...

Страница 14: ...on bottom of spark generator D Remove 2 mounting screws and remove generator assembly E Reassemble in reverse order and check system operation IGNITER SENSOR REPLACEMENT A Remove appropriate control b...

Страница 15: ...push out C Remove wires from back of switch note wire number and location D Reassemble in reverse order and check system operation NOTE Make sure switch housing is fully seated in control box housing...

Страница 16: ...operation TEMPERATURE SETTING FOR NEW TEMPERATURE CONTROL BOARD PROCEDURE FOR SETTING MAXIMUM TEMPERATURE POTENTIOMETER NOTE When replacing temp control turn oven temperature control to its maximum he...

Страница 17: ...thermocouple from wire form in oven chamber and remove from chamber NOTE R H thermocouple viewed from front is connected directly to the temperature control board remove 2 wires make note of wire colo...

Страница 18: ...0 10 57 11 35 12 89 14 43 15 97 74 F 3 72 5 23 6 76 7 52 8 29 9 83 10 60 11 37 12 92 14 46 15 99 72 F 3 78 5 29 6 82 7 58 8 35 9 89 10 66 11 43 12 97 14 51 16 05 T 70 F 3 83 5 34 6 87 7 63 8 40 9 95 1...

Страница 19: ...Low Profile 1600 Advantage Series Service Manual International 19 This page intentionally left blank...

Страница 20: ...return U L L R S N 35950 Below 370663 Baffle air return U L S N 35951 Above U 370166 Baffle air return U R L L S N 35950 Below 370662 Baffle air return U R S N 35951 Above V 370168 Finger housing T 1...

Страница 21: ...Low Profile 1600 Advantage Series Service Manual International 21...

Страница 22: ...Air pressure switch P 369154 Circuit breaker 7A Q 369192 Capacitor R 357107 Fuse holder S 369013 Fuse 3A 369014 Fuse 10A T 369507 Thermostat cooling fan U 369431 Thermostat control box hi limit V 3701...

Страница 23: ...Low Profile 1600 Advantage Series Service Manual International 23...

Страница 24: ...se 10A H 369368 Thermostat hi limit I 369378 cooling fan J 369192 Capacitor K 370296 Wire hanger L 369575 Air pressure switch M 369025 Air pressure switch N 369580 Gas valve O 369571 Connector P 36958...

Страница 25: ...Low Profile 1600 Advantage Series Service Manual International 25...

Страница 26: ...ockwise rotation C 369776 Fan shroud D 369777 Stand off E 369778 Rear wall assy F 369761 Motor mount G 369759 Motor main fan 220 240V 50 Hz H 1627 Duct cap I 369033 Motor clamp J 370245 Rear duct K 37...

Страница 27: ...Low Profile 1600 Advantage Series Service Manual International 27...

Страница 28: ...mplete conveyor A 369816 Conveyor belting B 369825 Belt 1ft section C 369813 Conveyor bearing block D 369314 Roll conveyor notched E 369812 Conveyor idler shaft F 369160 Conveyor pan stop G 369814 Con...

Страница 29: ...Low Profile 1600 Advantage Series Service Manual International 29...

Страница 30: ...Low Profile 1600 Advantage Series Service Manual International 30 This page intentionally left blank...

Страница 31: ...Low Profile 1600 Advantage Series Service Manual International 31 This page intentionally left blank...

Страница 32: ...Low Profile 1600 Advantage Series Service Manual International 32...

Отзывы: