Lincoln Impinger Conveyor Ovens 1633-000-EA Скачать руководство пользователя страница 10

Low Profile – 1600 Advantage Series Service Manual – International 

10 

 

 

 

 

gear motor 

 

 

and the motor does not run, first check 

 

 

 

 

 

 

 

 

the mini breaker and then the conveyor. 

 

 

 

 

 

 

 

 

Refer to the next possible cause. Check  

 

 

 

 

 

 

 

 

the leads to the motor for evidence of 

 

 

 

 

 

 

 

 

any shorts or opens , and each lead to  

 

 

 

 

 

 

 

 

ground. Check motor brushes . From  

 

 

 

 

 

 

 

 

the top of the motor, rotate motor shaft 

 

 

 

 

 

 

 

 

to determine if there is a locked rotor 

 

 

 

 

 

 

 

 

or a locked gearbox (use care so magnet 

 

 

 

 

 

 

 

 

and Hall Effect sensor board are not 

 

 

 

 

 

 

 

 

damaged). Replace motor as needed. 

 

 

 

 

Conveyor 

 

 

Check for any mechanical misalignment. 

 

 

 

 

 

 

 

 

Also, check for worn bearings.  

 

 

 

 

 

 

 

 

A conveyor belt that is over tightened 

 

 

 

 

 

 

 

 

will cause excessive bearing wear and 

 

 

 

 

 

 

 

 

sometimes, irregular speed. 

Conveyor speed varying  

Power supply   

 

Check power supply at the D.C. control 

or intermittent    

 

 

 

 

 

board for supply voltage at board terminals  

 

 

 

 

 

 

 

 

L1 and L2. 

 

 

 

 

Motor control board 

 

Place the test meter probes on terminals 

 

 

 

 

 

 

 

 

A+ and A-. (with speed potentiometer 

 

 

 

 

 

 

 

 

set to maximum speed – approximately 

 

 

 

 

 

 

 

 

2 min.). The meter reading should be 

 

 

 

 

 

 

 

 

approximately 100VDC(

±

3%), if  

 

 

 

 

 

 

 

 

voltage is not steady within limits, 

 

 

 

 

 

 

 

 

then the board is usually bad. 

 

 

 

 

 

 

 

 

Always check the speed potentiometer, 

 

 

 

 

 

 

 

 

be sure it is OK before changing a 

 

 

 

 

 

 

 

 

control board. This test is not always  

 

 

 

 

 

 

 

 

100% accurate as this test is not  

 

 

 

 

 

 

 

 

performed at operating speeds, However, 

 

 

 

 

 

 

 

 

this test is the best method currently 

 

 

 

 

 

 

 

 

available. 

 

 

 

 

D.C. Gearmotor  

 

If the D.C. control board is steady, 

 

 

 

 

 

 

 

 

then the problem may be the motor or  

 

 

 

 

 

 

 

 

gearbox. Check the brushes in the  

 

 

 

 

 

 

 

 

motor for excessive arching or  

 

 

 

 

 

 

 

 

unusual wear. Check the motor and  

 

 

 

 

 

 

 

 

gearbox from instructions located on 

 

 

 

 

 

 

 

 

page 9 under “possible cause”  

 

 

 

 

 

 

 

 

listing “conveyor gear motor” 

 

 

 

 

Magnet  

 

 

Check to insure that the magnet  

 

 

 

 

 

 

 

 

(cemented to shaft of conveyor drive  

 

 

 

 

 

 

 

 

motor) has not been damaged, or come 

 

 

 

 

 

 

 

 

loose from the motor shaft. Replace 

 

 

 

 

 

 

 

 

as needed.  

 

 

 

 

Hall Effect  

 

 

Check for any physical damage to    

 

 

 

 

Sensor   

 

 

hall effect sensor (mounted on  

 

 

 

 

 

 

 

 

conveyor drive motor). Check all  

 

 

 

 

 

 

 

 

wiring and connections for tightness 

 

 

 

 

 

 

 

 

and proper location. Replace as needed. 

 

 

 

 

 

 

 

 

Connect new hall effect to system  

 

 

 

 

 

 

 

 

and check for steady operation. 

Temperature display 

 

Display transformer 

 

Measure the transformer primary 

inoperative  

 

 

 

 

 

 

for supply voltage input. If voltage is  

 

 

 

 

 

 

 

 

not present, trace wiring back to the 

 

 

 

 

 

 

 

 

fan relay. If voltage is present,  

 

 

 

 

 

 

 

 

measure the secondary output of the 

 

 

 

 

 

 

 

 

transformer. Voltage across terminals 

 

 

 

 

 

 

 

 

1-3 should be 12-15VAC. Terminals 

 

 

 

 

 

 

 

 

1-2 and 2-3 should be ½  the voltage  

 

 

 

 

 

 

 

 

reading from terminals 1-3. If the above  

Содержание Impinger Conveyor Ovens 1633-000-EA

Страница 1: ...ENS LOW PROFILE 1600 INTERNATIONAL ADVANTAGE Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax...

Страница 2: ...E AND PARTS MANUAL 1600 INTERNATIONAL ADVANTAGE SEQUENCE OF OPERATIONS 3 SCHEMATIC 5 TROUBLESHOOTING GUIDE 6 REMOVAL INSTALLATION ADJUSTMENTS 12 GENERAL PARTS 20 ADVANTAGE SERIES 20 CONTROL BOX RIGHT...

Страница 3: ...zes two complete burner temperature control systems The sequence of operations is the same for each system Closing the main fan switch supplies line voltage through the oven power relay through a thre...

Страница 4: ...eyor control uses a sensor and magnet mounted on the conveyor motor that senses motor speed Any change in motor load RPM is detected by the sensor and the voltage to the motor is adjusted accordingly...

Страница 5: ...Low Profile 1600 Advantage Series Service Manual International 5 SCHEMATIC MODELS 1633 000 EA AND 1634 000 EA...

Страница 6: ...insure the contacts are closing Capacitor s Check for opens shorts or grounds Motor s Check for opens shorts or grounds No control box cooling Fan switch SEE OVEN Hi limit FAN WILL Oven fan relay NOT...

Страница 7: ...i limit Ignition control Check for supply voltage to ignition control at terminal 1 and neutral If voltage is not present trace wiring back to hi limit thermostat Check for supply voltage at terminal...

Страница 8: ...rrent but the burner will not remain ignited check the reset button on ignition control NOTE Check for proper polarity of the power supply If all of the above are OK replace ignition control Pilot lam...

Страница 9: ...Check for supply voltage input to filter If there is no voltage trace wiring back to relay If there is input voltage check for output voltage If there is input voltage but no output voltage replace f...

Страница 10: ...eck the speed potentiometer be sure it is OK before changing a control board This test is not always 100 accurate as this test is not performed at operating speeds However this test is the best method...

Страница 11: ...Temperature display Thermocouple Connect the thermocouple of a Inaccurate erratic pyrometer to the thermocouple on Or inoperative the temperature control board be sure to maintain proper polarity of...

Страница 12: ...n reverse order and check system operation AIR PRESSURE SWITCH REPLACEMENT A Remove control panel top B Disconnect wires from switch making note of wire number and location for reinstallation C Remove...

Страница 13: ...or and mark for reassembly E Remove sprocket from motor shaft F Remove 4 screws and remove conveyor motor and mounting bracket G Remove mounting bracket from conveyor motor assembly H Reassemble in re...

Страница 14: ...on bottom of spark generator D Remove 2 mounting screws and remove generator assembly E Reassemble in reverse order and check system operation IGNITER SENSOR REPLACEMENT A Remove appropriate control b...

Страница 15: ...push out C Remove wires from back of switch note wire number and location D Reassemble in reverse order and check system operation NOTE Make sure switch housing is fully seated in control box housing...

Страница 16: ...operation TEMPERATURE SETTING FOR NEW TEMPERATURE CONTROL BOARD PROCEDURE FOR SETTING MAXIMUM TEMPERATURE POTENTIOMETER NOTE When replacing temp control turn oven temperature control to its maximum he...

Страница 17: ...thermocouple from wire form in oven chamber and remove from chamber NOTE R H thermocouple viewed from front is connected directly to the temperature control board remove 2 wires make note of wire colo...

Страница 18: ...0 10 57 11 35 12 89 14 43 15 97 74 F 3 72 5 23 6 76 7 52 8 29 9 83 10 60 11 37 12 92 14 46 15 99 72 F 3 78 5 29 6 82 7 58 8 35 9 89 10 66 11 43 12 97 14 51 16 05 T 70 F 3 83 5 34 6 87 7 63 8 40 9 95 1...

Страница 19: ...Low Profile 1600 Advantage Series Service Manual International 19 This page intentionally left blank...

Страница 20: ...return U L L R S N 35950 Below 370663 Baffle air return U L S N 35951 Above U 370166 Baffle air return U R L L S N 35950 Below 370662 Baffle air return U R S N 35951 Above V 370168 Finger housing T 1...

Страница 21: ...Low Profile 1600 Advantage Series Service Manual International 21...

Страница 22: ...Air pressure switch P 369154 Circuit breaker 7A Q 369192 Capacitor R 357107 Fuse holder S 369013 Fuse 3A 369014 Fuse 10A T 369507 Thermostat cooling fan U 369431 Thermostat control box hi limit V 3701...

Страница 23: ...Low Profile 1600 Advantage Series Service Manual International 23...

Страница 24: ...se 10A H 369368 Thermostat hi limit I 369378 cooling fan J 369192 Capacitor K 370296 Wire hanger L 369575 Air pressure switch M 369025 Air pressure switch N 369580 Gas valve O 369571 Connector P 36958...

Страница 25: ...Low Profile 1600 Advantage Series Service Manual International 25...

Страница 26: ...ockwise rotation C 369776 Fan shroud D 369777 Stand off E 369778 Rear wall assy F 369761 Motor mount G 369759 Motor main fan 220 240V 50 Hz H 1627 Duct cap I 369033 Motor clamp J 370245 Rear duct K 37...

Страница 27: ...Low Profile 1600 Advantage Series Service Manual International 27...

Страница 28: ...mplete conveyor A 369816 Conveyor belting B 369825 Belt 1ft section C 369813 Conveyor bearing block D 369314 Roll conveyor notched E 369812 Conveyor idler shaft F 369160 Conveyor pan stop G 369814 Con...

Страница 29: ...Low Profile 1600 Advantage Series Service Manual International 29...

Страница 30: ...Low Profile 1600 Advantage Series Service Manual International 30 This page intentionally left blank...

Страница 31: ...Low Profile 1600 Advantage Series Service Manual International 31 This page intentionally left blank...

Страница 32: ...Low Profile 1600 Advantage Series Service Manual International 32...

Отзывы: