Low Profile – 1600 Advantage Series Service Manual – International

 

 

 

 

 

Fuse holder 

 

 

Check, replace if necessary. 

 

 

 

 

Gas pressure switch 

 

Check for supply voltage to neutral 

 

 

 

 

(internal to gas valve)   

on both sides of switch. If voltage is 

 

 

 

 

 

 

 

 

present on one side of switch only, 

 

 

 

 

 

 

 

 

check the following. Check for proper  

 

 

 

 

 

 

 

 

gas pressure supply to gas valve.(Marked  

 

 

 

 

 

 

 

 

on oven spec. plate.) Check for proper  

 

 

 

 

 

 

 

 

adjustment of gas pressure switch.  

 

 

 

 

 

 

 

 

should be set at 10 Nat., 27 for L.P. 

 

 

 

 

 

 

 

 

 

or 4.5 for town gas. Check gas filter in  

 

 

 

 

 

 

 

 

gas valve for blockage or damage. (See 

 

 

 

 

 

 

 

 

Adjustment section for location.) 

 

 

 

 

 

 

 

 

If the above checks OK, but switch is 

 

 

 

 

 

 

 

 

still not closed replace gas valve. 

 

 

 

 

Oven air pressure switch 

 

Check for supply voltage on both sides 

 

 

 

 

 

 

 

 

of switch. If voltage is present on one  

 

 

 

 

 

 

 

 

side only, check for air tube blockage. 

 

 

 

 

 

 

 

 

Adjust air pressure switch. If the above 

fails, replace air pressure switch. 

 

 

 

 

Hi-limit thermostat 

 

Terminals are normally closed. If open, 

 

 

 

 

 

 

 

 

reset and test oven for proper operation.  

 

 

 

 

 

 

 

 

If thermostat will not hold for maximum 

 

 

 

 

 

 

 

 

oven temperature, and oven is not  

 

 

 

 

 

 

 

 

exceeding maximum temperature dial  

 

 

 

 

 

 

 

 

setting, check for proper location of 

 

 

 

 

 

 

 

 

capillary bulb in its spring holder. 

 

 

 

 

 

 

 

 

If above checks OK, replace hi-limit. 

 

 

 

 

Ignition control   

 

Check for supply voltage to ignition  

 

 

 

 

 

 

 

 

control at terminal #1 and neutral. 

 

 

 

 

 

 

 

 

If voltage is not present, trace wiring  

 

 

 

 

 

 

 

 

back to hi-limit thermostat. Check for  

 

 

 

 

 

 

 

 

supply voltage at terminal #6 to neutral. 

 

 

 

 

 

 

 

 

If no voltage is present, wait 30 seconds 

 

 

 

 

 

 

 

 

and check reset button. If above fails,  

 

 

 

 

 

 

 

 

replace ignition control. 

 

 

 

 

Burner reset switch 

 

Switch is normally open. Check to see 

 

 

 

 

 

 

 

 

that the switch closes when reset button  

 

 

 

 

 

 

 

 

is pushed. Replace as needed. 

 

 

 

 

Burner blower motor 

 

Check for supply voltage to burner  

 

 

 

 

 

 

 

 

blower motor. 

 

 

 

 

 

 

 

 

WITH POWER OFF: Turn blower  

 

 

 

 

 

 

 

 

wheel to check for locked rotor. If  

 

 

 

 

 

 

 

 

supply voltage is present and motor does  

 

 

 

 

 

 

 

 

not run, replace motor. 

 

 

 

 

Burner blower motor 

 

Check for supply voltage switching to 

 

 

 

 

Air pressure switch 

 

terminal N. O. as the air pressure switch 

 

 

 

 

 

 

 

 

closes. Check for air tube blockage or 

 

 

 

 

 

 

 

 

misalignment, adjust air pressure switch. 

 

 

 

 

 

 

 

 

If the above fails, replace air pressure 

 

 

 

 

 

 

 

 

switch. 

 

 

 

 

Spark generator  

 

After a pre-purge time of 30 to 60  

 

 

 

 

 

 

 

 

seconds after blower motor starts, 

 

 

 

 

 

 

 

 

check for supply voltage to spark 

 

 

 

 

 

 

 

 

generator. If voltage is not present, 

 

 

 

 

 

 

 

 

Check reset button located on rear of  

 

 

 

 

 

 

 

 

control box. If voltage is still not 

 

 

 

 

 

 

 

 

present, replace ignition control. 

 

 

 

 

 

 

 

 

If voltage is present, visually check  

 

 

 

 

 

 

 

 

for spark at igniter head. 

 

 

 

 

Igniter/sensor assembly  

Check for visible damage to igniter/ 

 

 

 

 

 

 

 

 

sensor assembly. If there is no visible 

 

 

 

 

 

 

 

 

damage to the components, and no spark, 

Содержание Impinger Conveyor Ovens 1633-000-EA

Страница 1: ...ENS LOW PROFILE 1600 INTERNATIONAL ADVANTAGE Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax...

Страница 2: ...E AND PARTS MANUAL 1600 INTERNATIONAL ADVANTAGE SEQUENCE OF OPERATIONS 3 SCHEMATIC 5 TROUBLESHOOTING GUIDE 6 REMOVAL INSTALLATION ADJUSTMENTS 12 GENERAL PARTS 20 ADVANTAGE SERIES 20 CONTROL BOX RIGHT...

Страница 3: ...zes two complete burner temperature control systems The sequence of operations is the same for each system Closing the main fan switch supplies line voltage through the oven power relay through a thre...

Страница 4: ...eyor control uses a sensor and magnet mounted on the conveyor motor that senses motor speed Any change in motor load RPM is detected by the sensor and the voltage to the motor is adjusted accordingly...

Страница 5: ...Low Profile 1600 Advantage Series Service Manual International 5 SCHEMATIC MODELS 1633 000 EA AND 1634 000 EA...

Страница 6: ...insure the contacts are closing Capacitor s Check for opens shorts or grounds Motor s Check for opens shorts or grounds No control box cooling Fan switch SEE OVEN Hi limit FAN WILL Oven fan relay NOT...

Страница 7: ...i limit Ignition control Check for supply voltage to ignition control at terminal 1 and neutral If voltage is not present trace wiring back to hi limit thermostat Check for supply voltage at terminal...

Страница 8: ...rrent but the burner will not remain ignited check the reset button on ignition control NOTE Check for proper polarity of the power supply If all of the above are OK replace ignition control Pilot lam...

Страница 9: ...Check for supply voltage input to filter If there is no voltage trace wiring back to relay If there is input voltage check for output voltage If there is input voltage but no output voltage replace f...

Страница 10: ...eck the speed potentiometer be sure it is OK before changing a control board This test is not always 100 accurate as this test is not performed at operating speeds However this test is the best method...

Страница 11: ...Temperature display Thermocouple Connect the thermocouple of a Inaccurate erratic pyrometer to the thermocouple on Or inoperative the temperature control board be sure to maintain proper polarity of...

Страница 12: ...n reverse order and check system operation AIR PRESSURE SWITCH REPLACEMENT A Remove control panel top B Disconnect wires from switch making note of wire number and location for reinstallation C Remove...

Страница 13: ...or and mark for reassembly E Remove sprocket from motor shaft F Remove 4 screws and remove conveyor motor and mounting bracket G Remove mounting bracket from conveyor motor assembly H Reassemble in re...

Страница 14: ...on bottom of spark generator D Remove 2 mounting screws and remove generator assembly E Reassemble in reverse order and check system operation IGNITER SENSOR REPLACEMENT A Remove appropriate control b...

Страница 15: ...push out C Remove wires from back of switch note wire number and location D Reassemble in reverse order and check system operation NOTE Make sure switch housing is fully seated in control box housing...

Страница 16: ...operation TEMPERATURE SETTING FOR NEW TEMPERATURE CONTROL BOARD PROCEDURE FOR SETTING MAXIMUM TEMPERATURE POTENTIOMETER NOTE When replacing temp control turn oven temperature control to its maximum he...

Страница 17: ...thermocouple from wire form in oven chamber and remove from chamber NOTE R H thermocouple viewed from front is connected directly to the temperature control board remove 2 wires make note of wire colo...

Страница 18: ...0 10 57 11 35 12 89 14 43 15 97 74 F 3 72 5 23 6 76 7 52 8 29 9 83 10 60 11 37 12 92 14 46 15 99 72 F 3 78 5 29 6 82 7 58 8 35 9 89 10 66 11 43 12 97 14 51 16 05 T 70 F 3 83 5 34 6 87 7 63 8 40 9 95 1...

Страница 19: ...Low Profile 1600 Advantage Series Service Manual International 19 This page intentionally left blank...

Страница 20: ...return U L L R S N 35950 Below 370663 Baffle air return U L S N 35951 Above U 370166 Baffle air return U R L L S N 35950 Below 370662 Baffle air return U R S N 35951 Above V 370168 Finger housing T 1...

Страница 21: ...Low Profile 1600 Advantage Series Service Manual International 21...

Страница 22: ...Air pressure switch P 369154 Circuit breaker 7A Q 369192 Capacitor R 357107 Fuse holder S 369013 Fuse 3A 369014 Fuse 10A T 369507 Thermostat cooling fan U 369431 Thermostat control box hi limit V 3701...

Страница 23: ...Low Profile 1600 Advantage Series Service Manual International 23...

Страница 24: ...se 10A H 369368 Thermostat hi limit I 369378 cooling fan J 369192 Capacitor K 370296 Wire hanger L 369575 Air pressure switch M 369025 Air pressure switch N 369580 Gas valve O 369571 Connector P 36958...

Страница 25: ...Low Profile 1600 Advantage Series Service Manual International 25...

Страница 26: ...ockwise rotation C 369776 Fan shroud D 369777 Stand off E 369778 Rear wall assy F 369761 Motor mount G 369759 Motor main fan 220 240V 50 Hz H 1627 Duct cap I 369033 Motor clamp J 370245 Rear duct K 37...

Страница 27: ...Low Profile 1600 Advantage Series Service Manual International 27...

Страница 28: ...mplete conveyor A 369816 Conveyor belting B 369825 Belt 1ft section C 369813 Conveyor bearing block D 369314 Roll conveyor notched E 369812 Conveyor idler shaft F 369160 Conveyor pan stop G 369814 Con...

Страница 29: ...Low Profile 1600 Advantage Series Service Manual International 29...

Страница 30: ...Low Profile 1600 Advantage Series Service Manual International 30 This page intentionally left blank...

Страница 31: ...Low Profile 1600 Advantage Series Service Manual International 31 This page intentionally left blank...

Страница 32: ...Low Profile 1600 Advantage Series Service Manual International 32...

Отзывы: