A-2
INSTALLATION
IDEALARC® DC-1000
A-2
This equipment is for industrial use only and it is not
intended for use in residential locations where the
electrical power is provided by the public low-voltage
supply system. There can be potential difficulties in
residential locations due to conducted as well as radi-
ated radio-frequency disturbances. The EMC or RF
classification of this equipment is Class A.
STACKING
Two DC-1000’s may be stacked by observing the
following safety precautions:
1. Make sure the first or bottom unit is setting on a
level, well-supported surface.
2. The units must be stacked with their fronts flush,
making sure the two holes in the base rails of the
top unit are over the two pins located on top of the
bottom unit.
INPUT WIRING
Be sure the voltage, phase and frequency of the input
power is as specified on the welder nameplate.
Dual voltage (e.g. 380/440) models are shipped
connected for the highest voltage. To change the
connection, see the connection diagram pasted to the
inside of the access panel in the case back.
Have a qualified electrician remove the rear access
panel and connect 3 phase AC power to terminals L1,
L2 and L3 of the input panel in accordance with the
U.S. National Electrical Code, all local codes and the
wiring diagram located inside the machine.
The welder frame must be grounded. A stud marked
with the symbol located inside the machine near
the input panel is provided for this purpose. See the
U.S. National Electrical Code for details on proper
grounding methods. See Technical Specifications for
recommended input wire and fuse sizes.
SAFETY PRECAUTIONS
Read this entire installation section before you
start installation.
ELECTRIC SHOCK can kill.
• Only qualified personnel should
perform this installation.
• Turn the input power OFF at the
disconnect switch or fuse box
before working on this equipment.
Turn off the input power to any
other equipment connected to the
welding system at the disconnect
switch or fuse box before working
on the equipment.
• Do not touch electrically hot parts.
• Always connect the grounding lug (located
inside the reconnect input access door) to a
proper safety (Earth) ground.
-----------------------------------------------------------------------
FALLING EQUIPMENT
can cause
injury.
• Do not lift this machine using lift bale if
it is equipped with a heavy accessory
such as trailer or gas cylinder.
• Lift only with equipment of adequate lifting capacity.
• Be sure machine is stable when lifting.
• Do not stack more than two high.
• Do not stack the DC-1000 on top of any other
machine.
---------------------------------------------------------------------
WARNING
LOCATION
Even though the machine is designed to operate
under a wide variety of environmental conditions, for
maximum reliability and long life the machine should
be located in a clean, dry place where there is free
circulation of clean air in through the front and out the
back of the machine. Dirt and dust that can be drawn
into the machine should be kept to a minimum. Failure
to observe these precautions can result in excessive
operating temperatures and nuisance shutdown of the
machine.
The case front incorporates a recessed control panel
which protects the controls and minimizes the possi-
bilities of accidental contact. This cover panel can be
flipped open to permit access to the enclosed control
section.
The individual case sides are removable for easy
access for internal service or inspection.
The case rear is equipped with a removable cover
plate, permitting easy access to the input panel.
The machine uses a 38” (965mm) long base. The low
profile case facilitates installation of the machine
under a workbench and stacking the machines two
high to conserve floor space.
A permanent lifting eye is located at the top of the
machine and is positioned so that it acts as nearly as
possible through the center of gravity. This lift eye fits
under the case of the second machine without inter-
ference when stacking.
WARNING
Содержание IDEALARC DC-1000
Страница 7: ...7 NOTES IDEALARC DC 1000 7 ...
Страница 31: ...P 720 A jpg Index of Sub Assemblies 12480 2 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 33: ...No Image Miscellaneous Items 4 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 37: ...P 720 C_2 jpg Case Front Control Box 8 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 40: ...P 720 D jpg Case Back Assembly DC 1000 12480 11 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 42: ...P 720 E jpg Base Fan Roof and Case Sides DC 1000 12480 13 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 44: ...P 720 F jpg Output Rectifier Choke Assembly DC 1000 12480 15 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 47: ...P 720 G jpg Lift Bale Transformer Assembly 18 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 49: ...P 720 H jpg S78 Contactor 20 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...