D-1
MAINTENANCE
D-1
The control board is designed with adequate
protection so that no damage will occur if the remote
control leads are shorted together or are grounded to
the case. The machine will automatically shut down if
such faults do occur.
An 8-amp fuse located on the machine control panel
protects the 115 volt auxiliary AC circuit (#31 and #32)
from overload. If replacing, use the same type and
size fuse.
IDEALARC® DC-1000
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
• Only qualified personnel should
perform this installation.
• Turn the input power OFF at the
disconnect switch or fuse box before
working on this equipment.
• Do not touch electrically hot parts.
------------------------------------------------------------------------
GENERAL MAINTENANCE
1. The fan motors have sealed bearings which
require no service.
2. In extremely dusty locations, dirt may clog the air
channels causing the welder to run hot. Blow out
the welder with low pressure air at regular
intervals as required to eliminate excessive dirt
and dust buildup on internal parts.
OVERLOAD PROTECTION AND THERMAL
PROTECTION LIGHT
The power source is thermostatically protected with
two proximity thermostats against overload or insuf-
ficient cooling. One thermostat is located on the
transformer secondary negative output lead, and the
other thermostat is located on the choke coil. The
thermostats are connected in series in the machine
control circuit so that if an excessive overload is
applied to the machine, or the machine should receive
insufficient cooling on either the main transformer,
SCR bridge assembly or choke, the input contactor
would open and remain open until the machine cools.
Pressing the “On” button will illuminate an amber light
on the front of the machine indicating that one of the
thermostats has opened. Once the machine cools, it
can be manually restarted by operating the start push
button.
The power source is also protected against heavy
overloads on the SCR bridge assembly through an
electronic protection circuit. This circuit senses an
overload on the power source and opens the input
contactor should the overload remain for a prede-
termined time. The predetermined time varies with the
amount of overload; the greater the overload, the
shorter the time. The input contactor will remain open
until the power source is manually started with the
start push button.
WARNING
Содержание IDEALARC DC-1000
Страница 7: ...7 NOTES IDEALARC DC 1000 7 ...
Страница 31: ...P 720 A jpg Index of Sub Assemblies 12480 2 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 33: ...No Image Miscellaneous Items 4 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 37: ...P 720 C_2 jpg Case Front Control Box 8 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 40: ...P 720 D jpg Case Back Assembly DC 1000 12480 11 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 42: ...P 720 E jpg Base Fan Roof and Case Sides DC 1000 12480 13 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 44: ...P 720 F jpg Output Rectifier Choke Assembly DC 1000 12480 15 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 47: ...P 720 G jpg Lift Bale Transformer Assembly 18 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...
Страница 49: ...P 720 H jpg S78 Contactor 20 DC 1000 12480 Printed 09 24 2015 at 08 32 31 Produced by Enigma ...