E-2
TROUBLE SHOOTING
Observe all Safety Guidelines detailed throughout this manual
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.
CAUTION
SQUARE WAVE
®
TIG 200
PROBLEM
POSSIBLE CAUSE
RECOMMENDED
COURSE OF ACTION
Machine is Dead -
No Output - No Fan
1. Make certain that the input power switch is in the “ON” position and
machine is plugged in.
Contact your Local
Lincoln
Authorized Field Service
Facility
for technical
troubleshooting assistance.
2. Check the input voltage at the machine. Input voltage must match
the rating plate and voltage connection. Refer to the Installation
section of this manual.
3. Blown or missing fuses in input line.
Fan runs - No output from
machine in either Stick or TIG
modes.
1. Check for proper input voltages per nameplate and voltage recon-
nection.
2. Check to make sure cables are firmly connected.
Fan runs - No output from
machine in either Stick or TIG
modes and the yellow light on
the control panel is on or
flashing while welding.
1. Welding application may have exceed the recommended duty cycle.
Allow the unit to run until the fan cools the unit and the yellow light
goes out.
Machine does not respond
(no gas flow, no high
frequency and no open circuit
voltage) when arc start switch
or Amptrol is activated - fan
is working.
1. Machine MUST be in AC or DC TIG Mode.
2. The Amptrol may be defective. Check for continuity between pins
“D” and “E” on cable connector when Amptrol is depressed.
Machine regularly over heats
- thermostat opens, Yellow
light on front panel
illuminates or flashes. The
fan runs but machine has no
output.
1. Welding application may exceed recommended duty cycle. Reduce
the duty cycle.
2. Dirt and dust may have clogged the cooling channels inside the
machine. Blow out unit with clean, dry low pressure air.
3. Air intake, brickwork and exhaust louvers may be blocked due to
inadequate clearance around machine.
Machine output is inter-
mittently lost.
1. Check Amptrol for proper operation and loose connections.
2. Check for proper input voltage and proper voltage reconnection.
Содержание Square Wave TIG 200
Страница 24: ...F 2 DIAGRAMS SQUARE WAVE TIG 200 10 80 14 03 19 98 DIMENSIONAL PRINT ...
Страница 48: ...F 2 DIAGRAMAS SQUARE WAVE TIG 200 10 80 14 03 19 98 DIMENSIONES ...
Страница 71: ...Square Wave TIG 200 12475 ...
Страница 76: ...P 896 C jpg Case Front Assembly 6 Square Wave TIG 200 12475 Printed 10 01 2015 at 09 18 46 Produced by Enigma ...
Страница 81: ...P 896 E jpg Wraparound Assembly Square Wave TIG 200 12475 11 Printed 10 01 2015 at 09 18 46 Produced by Enigma ...