Section 4: Operation with Automatic Gas Console
Spirit II User’s Manual
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
4-14
Advanced Config Tab
Press the Config navigation button followed by the Advanced Config tab to access the
screen described below.
Set RS422 Node
When multiple Spirit systems are being used together on an RS-422 serial
communication link, each system must have a unique identification number (node
number) to identify itself to the network. To set the communication node number,
simply choose from node 1 through 8.
When using an Inova torch height control system with the Spirit, the communication
node feature must be disabled. To disable the communication node, press the Disabled
button.
Set CAN Domain
Make sure the CAN domain is set to 1. All other selections are for future use.
Torch Selection
Choose which type of Quick-Disconnect head is being used. The type of head
corresponds to the type of electrodes being used; either copper or silver.
Allow Error Suppression
Press Enable to allow error suppression. Press Disable to stop error suppression.
Arc Off Delay
In some instances, such as when cutting thicker stainless steel materials, it may
be desirable to delay the extinction of the cutting arc after a stop signal is
received. To program an arc off delay, press the data entry button ( ) and enter
the desired delay time in milliseconds. The delay can be set from 0 to 2000 mS.