Section 6: Maintenance &Troubleshooting
Spirit II User’s Manual
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
6-6
Power Supply Microprocessor (DSP)
Sequence of Operation
The following DSP Indicators should illuminate after primary power is applied:
D77 ................................... 3.3V Supply
D78 ................................... 1.8V Supply
D50 ................................... ASC (Door)
D33 ................................... Coolant Level
D37 ................................... Arc Hold (if INOVA is being used)
D10 ................................... RS232 T1 Out (Blinking)
D11 ................................... CAN RXD (Dim Flashing)
D12 ................................... CAN TXD (Dim Flashing)
The following DSP Indicators should illuminate when the OFF Button is released:
D40 ................................... OFF Button
The following DSP Indicators should illuminate when the ON Button is activated:
Opto U21 .......................... Motor / Solenoid
Opto U19 .......................... Solenoid (not used)
Opto U26 .......................... Fan
D42 ................................... Plasma Ready
The following DSP Indicators should illuminate when a START signal is applied (begin
cut cycle):
D36 ................................... Start
Opto U27 .......................... Preflow
Opto U29 .......................... Shield
Opto U24 .......................... Surge (only over 100 amps)
Opto U23 .......................... Contactor
D24 ................................... PWM (Chopper ON)
Opto U22 .......................... Pilot Arc Relay ON
D43 ................................... PAT ON (Blinks during a START)
Opto U36/U37 ................... Impulse/RHF (Blinks during a START)
The following DSP Indicators should illuminate with an arc transfer:
Opto U31 .......................... Postflow
Opto U28 .......................... Plasma
D41 ................................... Motion
The following LEDs should turn OFF after the Motion Indicator turns ON:
Opto U36/U37 ................... Impulse/RHF
Opto U27 .......................... Preflow
D43 ................................... PAT
When the START signal is removed, OPTO U30 (Vent) will illuminate. It will then go out
with the rest of the cut cycle indicators.