A-1
INSTALLATION
POWER WAVE
®
S500
TECHNICAL SPECIFICATIONS - POWER WAVE
®
S500CE
INPUT
VOLTAGE / PHASE/
FREQUENCY
230/3/50/60
380-415/3/50/60
4
460/3/50/60
4
575/3/50/60
TIME DELAY FUSE
OR BREAKER
2
AMPERAGE
90
60
45
35
CORD SIZE
3
AWG SIZES
(mm
2
)
4 (21)
8 (10)
8 (10)
10 (7)
MAXIMUM INPUT
AMPERE RATING AND
DUTY CYCLE
67A, 40%
41A, 40%
34A, 40%
27A, 40%
RATED OUTPUT
POWER SOURCE-INPUT VOLTAGE AND CURRENT
Model
K3168-1
Duty Cycle
40% rating
100% rating
450 Amps
36.5 Volts
550 Amps
41.5 Volts
500
Amps
39 Volts
INPUT
VOLTAGE
/
PHASE/
FREQUENCY
230/3/50/60
380-415/3/50/60
460/3/50/60
575/3/50/60
*
Input Amperes
67/41/34/27
50/30/25/20
Idle Power
300 Watts Max.
(fan on)
Power Factor @
Rated Output
.95
Input Voltage ± 10%
230/400
*
460/575
50/60 Hz
(includes 380V to 415V)
*
For voltages higher than 460V or applications outside the European union replace input cord with properly
rated cable.
1
. Based on U.S. National electrical Code.
2
. Also called " inverse time" or "thermal / magnetic" circuit breakers; circuit breakers that have a delay in trip-
ping action that decreases as the magnitude of the current increases.
3
. Type SO cord or similar in 30
°
C ambient at effective current rating of unit.
4
. Supplied K3168-1 input cord for these input applications only. For all others consult chart and connect per
electrical code.
40%
60%
100%
GTAW-DC
450
Amps
38 Volts
550
Amps
42 Volts
500 Amps
40 Volts
40%
60%
100%
450 Amps
28 Volts
550 Amps
32 Volts
500 Amps
30 Volts
40%
60%
100%
RECOMMENDED INPUT WIRE AND FUSE SIZES
1
GMAW
SMAW