C-1

ACCESSORIES

POWER WAVE

®

S500

KITS, OPTIONS AND

ACCESSORIES

All Kits Options and Accessories are found on the Web site:
(www.lincolnelectric.com)

fACTORY INSTALLED

None Available

fIELD INSTALLED OPTIONS

GENERAL OPTIONS 

Stick / Tig User Interface Kit 

Mounts inside the front panel of the POWER WAVE® S500. Allows
stick and Tig operation without having a wire feeder.  

Order K3001-2  
DeviceNet  Kit 

Mounts inside the back of the POWER WAVE®
S500. Allows Devicenet objects to communicate
with the POWER WAVE® S500.  

Order K2827-2 
Work Voltage Sense Lead Kit 

Required to accurately monitor voltage at the arc.   

Order K940-XX Series

Order K1811-XX Series
Deluxe Adjustable Gas Regulator & Hose Kit 

Accommodates CO2, Argon, or Argon-blend gas cylinders.
Includes a cylinder pressure gauge, dual scale flow gauge and 4.3
ft. (1.3 m) gas hose. 

Order K586-1 
Coaxial Welding Cable

Optimum weld cables for minimizing cable inductance and
optimizing welding performance.

AWG 1/0 Coaxial Cables:

Order K1796-25 for 25 feet (7.6 m) cable length.

Order K1796-50 for 50 feet (15.2 m) cable length.

Order K1796-75 for 75 feet (22.9 m) cable length.

Order K1796-100 for 100 feet (30.5 m) cable length.

AWG #1 Coaxial Cables:

Order K2593-25 for 25 feet (7.6 m) cable length.

Order K2593-50 for 50 feet (15.2 m) cable length.

Order K2593-100 for 100 feet (30.5 m) cable length.

K2909-1

12-pin to 6-pin adapter.

K2910-1

12-pin to 7-pin adapter.

Welding Fume Extractors

Lincoln offers a wide range of fume extraction environmental
system solutions, ranging from portable systems easily wheeled
around a shop to shop-wide central systems servicing many
dedicated welding stations. 

Request Lincoln publication E13.40 (See www.lincolnelectric.com)

STICk OPTIONS

Accessory Kit - 150 Amp

For stick welding. Includes 20 ft. (6.1m) #6
electrode cable with lug, 15 ft. (4.6m) #6 work
cable with lugs, headshield, filter plate, work
clamp, electrode holder and sample pack of
mild steel electrode. 

ORDER K875
Accessory Kit - 400 Amp

For stick welding. Includes 35 ft. (10.7m) 2/0
electrode cable with lug, 30 ft. (9.1m) 2/0 work
cable with lugs, headshield, filter plate, work
clamp and electrode holder.  

ORDER K704
Remote Output Control 

Permits remote adjustment of output. 
Order K857-2 for 25 ft (7.6m) with 12 pin
connector.

TIg OPTIONS

Pro-Torch™ TIG Torches 

A full line of air-cooled and water-cooled torches available. 

Request Lincoln publication E12.150 (See
www.lincolnelectric.com)

Hand Amptrol® 

Provides 25 ft. (7.6 m) of remote current
control for TIG welding. Order K963-4 for
Hand Amptrol with 12 pin connector

Foot Amptrol® 

Provides 25 ft. (7.6 m) of remote current
control for TIG welding. Order K870-2 for
Foot Amptrol with 12 pin connector.

TIG-Mate™ 17V Air-Cooled TIG Torch

Starter Pack 

Get everything you need for TIG welding in one complete easy-to-
order kit packaged in its own portable carrying case. Includes:
PTA-17V torch, parts kit, Harris® flowmeter/regulator, 10 ft. (3.0
m) gas hose, and work clamp and cable. 
Order K2265-1  

COMPATIBLE LINCOLN EQUIPMENT

Any Arclink compatible wire feeding equipment

(See www.lincolnelectric.com)

Содержание POWER WAVE S500

Страница 1: ...having Code Numbers 12772 12773 12774 12775 Need Help Call 1 888 935 3877 to talk to a Service Representative Hours of Operation 8 00 AM to 6 00 PM ET Mon thru Fri After hours Use Ask the Experts at l...

Страница 2: ...A LARGE ROOM OR OUTDOORS natural ventilation may be adequate if you keep your head out of the fumes See below USE NATURAL DRAFTS or fans to keep the fumes away from your face If you develop unusual s...

Страница 3: ...rs and devices in position and in good repair Keep hands hair clothing and tools away from V belts gears fans and all other moving parts when starting operating or repairing equipment 1 e In some case...

Страница 4: ...to ANSI Z87 I standards 4 b Use suitable clothing made from durable flame resistant material to protect your skin and that of your helpers from the arc rays 4 c Protect other nearby personnel with su...

Страница 5: ...nt passing through lifting chains crane cables or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail 6 h Also see item 1 c 6 I Read and follow N...

Страница 6: ...i s et non inflamma bles 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pant...

Страница 7: ...t used for calibration or measurement g the immunity of other equipment in the environment The user shall ensure that other equipment being used in the environment is compatible This may require addit...

Страница 8: ...BOLS THAT APPEAR ON THIS MACHINE OR IN THIS MANUAL B 1 PRODUCT DESCRIPTION B 2 RECOMMENDED PROCESSES AND EQUIPMENT B 2 PROCESS LIMITATIONS B 2 EQUIPMENT LIMITATIONS B 2 DESIGN FEATURES B 2 S500 CASE F...

Страница 9: ...olts INPUT VOLTAGE PHASE FREQUENCY 200 208 3 50 60 230 3 50 60 380 415 3 50 60 460 3 50 60 575 3 50 60 Input Amperes 80 73 41 37 29 60 54 30 27 21 Idle Power 500 Watts Max fan on Power Factor Rated Ou...

Страница 10: ...00 Amps 39 Volts INPUT VOLTAGE PHASE FREQUENCY 380 415 3 50 60 460 3 50 60 575 3 50 60 Input Amperes 41 37 29 30 27 21 Idle Power 500 Watts Max fan on Power Factor Rated Output 95 Input Voltage 10 400...

Страница 11: ...an on Power Factor Rated Output 95 Input Voltage 10 230 400 460 575 50 60 Hz includes 380V to 415V For voltages higher than 460V or applications outside the European union replace input cord with prop...

Страница 12: ...ronmentally Hardened 40 F to 185 F 40C to 85C PROCESS GMAW GMAW Pulse FCAW GTAW DC SMAW OUTPUT RANGE AMPERES 40 550A 5 550A 15 550A OCV Uo Mean Peak 60V 100V 24V 60V WELDING PROCESS A 2 INSTALLATION P...

Страница 13: ...all sides This equipment is for industrial use only and it is not intended for use in residential locations where the electrical power is provided by the public low voltage supply system There can be...

Страница 14: ...rmal magnetic circuit breakers Choose input and grounding wire size according to local or national electrical codes Using input wire sizes fuses or circuit breakers smaller than recommended may result...

Страница 15: ...ds on the new power cord in the same location and with the same number of turns CONNECT EACH PHASE OF A THREE PHASE CONDUCTOR HERE INPUT POWER ACCESS DOOR INPUT CORD STRAIN RELIEF CE FILTER GROUND CON...

Страница 16: ...R R G GA AS S H HO OS SE E F FO OO OT T A AM MP PT TR RO OL L K K87 870 0 W WO OR RK K P PI IE EC CE E W WO OR RK K C CL LA AM MP P T TI IG G T TO ORC RCH H K K2 22 26 66 6 1 1 K KI IT T I INC NCL LUD...

Страница 17: ...rol panel can be installed into the power source Figure A 3 The connection diagram shown is based on the S Series user interface K3001 2 In this diagram the remote control box is optional REMOTE CONTR...

Страница 18: ...ails R RE EG GU UL LA AT TO OR R F FL LO OW WM ME ET TE ER R G GAS AS H HO OS SE E W WO OR RK K P PI IE EC CE E W WO OR RK K C CL LA AM MP P T TO O P PO OS SI IT TI IVE VE S ST TU UD D T TO O N NE EG...

Страница 19: ...e Always use the largest welding cables electrode and work that are practical and be sure all connections are clean and tight Note Excessive heat in the weld circuit indicates undersized cables and or...

Страница 20: ...te sense leads are connected With this feature there are no requirements for setting up the machine to use remote sense leads This feature can be disabled through the Weld Manager Utility available at...

Страница 21: ...The remote WORK sense lead 21 can be accessed through the four pin voltage sense connector located on the control panel by using the K940 Sense Lead Kit It must be attached to the work as close to th...

Страница 22: ...ads ARE Used Position the sense leads out of the path of the weld current Especially any current paths common to adjacent arcs Current from adjacent arcs can induce voltage into each others current pa...

Страница 23: ...AVE S500 For circumferential applications connect all work leads on one side of the weld joint and all of the work voltage sense leads on the opposite side such that they are out of the current path S...

Страница 24: ...the power source to the wire feeder The control cable consists of two power leads one twisted pair for digital communication and one lead for voltage sensing The 5 pin ArcLink connection on the Power...

Страница 25: ...rotection SEE ADDITIONAL WARNING INFORMATION UNDER ARC WELDING SAFETY PRECAUTIONS AND in the FRONT OF THIS OPERATING MANUAL POWER UP SEQUENCE When the POWER WAVE S500 is powered up it can take as long...

Страница 26: ...th an output range of 5 to 550 amperes it supports a number of standard processes including synergic GMAW GMAW P FCAW FCAW SS SMAW GTAW and GTAW P on various materials especially steel aluminum and st...

Страница 27: ...7 Work Sense lead CONNECTOR 8 12 Pin CONNECTOR optional FIGURE B 1 CASE BACk CONTROLS See Figure B 2 1 115 VAC CIRCUIT BREAKER 2 115 VAC RECEPTACLES 3 Reserved for future development 4 SYNC TANDEM ST...

Страница 28: ...ode Stud 7 Work Sense lead 8 12 PIN REMOTE optional FIGURE B 1 S500 CE S500 CE CASE BACk CONTROLS See Figure B 2 S500 CE 1 Gas Inlet optional 2 Reserved for future development 3 SYNC TANDEM STT CONNEC...

Страница 29: ...ng mode offers the simplicity of single knob control The machine will select the correct voltage and amperage based on the Wire Feed Speed WFS set by the operator Basic Welding Controls Weld Mode Sele...

Страница 30: ...wire feed speed a corresponding voltage is prepro grammed into the machine through special software at the factory The nominal preprogrammed voltage is the best average voltage for a given wire feed...

Страница 31: ...50 to 1 25 At very low or high wire feed speeds the adaptive range may be less due to reaching physical limitations of the welding process UltimArc Control adjusts the focus or shape of the arc UltimA...

Страница 32: ...ffers a wide range of fume extraction environmental system solutions ranging from portable systems easily wheeled around a shop to shop wide central systems servicing many dedicated welding stations R...

Страница 33: ...critical to its operation Generally speaking the calibration will not need adjustment However neglected or improperly calibrated machines may not yield satisfactory weld performance To ensure optimal...

Страница 34: ...USE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause generally it...

Страница 35: ...e system configuration is changed during operation Fast Blinking Green Indicates Auto mapping has failed Alternating Green and Red Non recoverable system fault If the Status lights are flashing any co...

Страница 36: ...contact the Service Department Review error code from input board status light or status beeper Most likely caused by an over power condition which caused an under voltage on the primary bus If cycli...

Страница 37: ...y a fan malfunction or blocked air vent Temporary 337 Precharge Timeout The DC bus voltage was not charged to a certain level at end of precharge If problem persists contact Service Department Persist...

Страница 38: ...ut current duty cycle or both 3 Contact your local authorized Lincoln Electric Field Service facility for technical assistance 1 Make sure input supply disconnect has been turned ON Check input fuses...

Страница 39: ...ections or faulty thermostats in the thermostat circuit 1 Replace the battery Type BS2032 1 Check for feeding problems 2 Check for bad connections excessive loops in cable etc NOTE The presence of hea...

Страница 40: ...g This condition will also result in a status light blinking See the Status Light section for more information 1 Make certain that the input voltage is proper according to the Rating Plate located on...

Страница 41: ...formation has been entered 2a Verify no duplicate the IP addresses exist on the network 3 Verify that the network device connected to the Power Wave is either a 10 baseT device or a 10 100 baseT devic...

Страница 42: ...5 4 8 1 2 1 6 6 12 1 J10A1 J10B1 J811 J2 J3 J4 J45 J61 J86 J2 J5 J11 J31 J46 J51 J111 J82 J81 J9 J13 J16 J26 J27 J62 J112 J83 J1 J8 J24 J28 J29 J43 J47 J63 J84 J12 J23 J25 J42 J6 J7 J41 J85 J87 INPUT...

Страница 43: ...2 HIGH C DIFF_2 LOW D E F 1 J50 2 3 4 357 354 352 349 B R R 250 OHM 25 W 250 OHM 25 W M20305 1 WORK 206E 206C 202 202B 67C 67D 67F J36 2 1 4 6 3 5 8 7 51A 9 10 12 J23B 8 11 3 4 5 6 7 2 13 14 15 16 1 3...

Страница 44: ...2 9 8 16 1 4 6 1 3 5 4 8 1 2 1 6 6 12 1 J10A1 J10B1 J811 J2 J3 J4 J45 J61 J86 J2 J5 J11 J31 J46 J51 J111 J82 J81 J9 J13 J16 J26 J27 J62 J112 J83 J1 J8 J24 J28 J29 J43 J47 J63 J84 J12 J23 J25 J42 J6 J7...

Страница 45: ...F 4 DIAGRAMS POWER WAVE S500 L16215 A 01 13 94 22 45 27 43 6 00 18 35 24 76 POWER WAVE S500 S500CCC DIMENSIONAL PRINT...

Страница 46: ...F 5 DIAGRAMS POWER WAVE S500 2 12 27 43 22 45 13 96 6 00 24 76 18 35 POWER WAVE S500 CE DIMENSIONAL PRINT...

Страница 47: ......

Страница 48: ......

Страница 49: ......

Страница 50: ...parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los electrodos bajo carga con la piel o ropa moja da l Aislese del trabajo y de la tierra...

Страница 51: ...d Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Use ventila o e exhaust o para remover fumo da zona respirat ria l Turn power off before servicing l Desconectar el cable de ali mentac...

Страница 52: ...tomer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any respon sibility for updating or correcting any such information o...

Отзывы: