8695 4598 / G
B - DESCRIPTION
CPM 400-450-600wi
B-5
Fluids:
Type
Use
Supply
pressure
Service
pressure
Flow
(max. use)
Purity
150A
300A
450A
-
-
Bar
Bar
l/min
Argon
- Plasma
pilot
gas
- Plasma
marking
9
1 to 6
30
65
80
99.998%
Oxygen
- Plasma
cutting
gas
- Plasma
shield
gas
9
0.5 to 7.5
21
30
50
99.5%
Nitrogen
- Plasma
cutting
gas
- Plasma
shield
gas
9
0.5 to 7
30
50
80
99.99%
N
2
H
2
(5%)
- Plasma
cutting
gas
9
3.5 to 4.5
15
15
15
99.99%
ArH2 20%
- Plasma
cutting
gas
- Plasma
shield
gas
9
0.5 to 3
30
55
70
99.99%
ArH2 35%
- Plasma
cutting
gas
- Plasma
shield
gas
9
0.5 to 7
40
40
40
99.99%
Argon &
Nitrogen
(
MIXOJET
)
Alimentation
du
MIXOJET
DUAL
12
-
32
44
56
99.99%
Hydrogen
(
MIXOJET
)
Alimentation
du
MIXOJET
DUAL
12
-
14
20
25
99.99%
Air
Plasma
shield
gas
9
0.5 to 5
50
130
200
Dry and oil
free
Water
Plasma
vortex
4
-
1.5
1.5
1.5
(*)
Freezcool
Cooling
150A-300A-
450A
-
7.5 to 8.5
4,0 l/min minimum
T°=22 à 23 °C
Freezcool
Friojet
300
Friojet
300
Friojet
720
(*): NATURE OF WATER VORTEX
The water used must be demineralised with neutral pH
(between 6.5 and 8.3), hardness below 10°F
and resistivity above 100 KΩ/cm²/cm.
Depending on the characteristics of the water,
use either a demineraliser,
or a reverse osmosis system or any other deionising
system.