B-3
OPERATION
B-3
•
The Arc Control regulates the Arc Force to adjust
the short circuit current. The minimum setting (-10)
will produce a "soft" arc and will produce minimal
spatter. The maximum setting (+10) will produce a
"crisp" arc and will minimize electrode sticking.
TIG GTAW: The TIG mode features continuous con-
trol from 5 to 570 amps. The TIG mode can be run in
either the TIG touch start or high frequency (optional
equipment required) assisted start mode.
•
The Hot Start control selects the starting mode
desired. A setting of less than 5, the TIG lift start
mode is selected. The OCV is controlled below 10v
and the short circuit "TIG touch" current is main-
tained at 25 amps independent of the preset cur-
rent.
When the tungsten is lifted, an arc is initiated and
the output is regulated at the preset value. Hot start
settings between 0 and 5 regulate the arc initiation
current. A setting of 5 results in the most positive
arc initiation. A setting of 0 reduces hot start.
•
Hot Start settings between 5 and 10, select high
frequency assisted starting TIG mode. In this
range, the OCV of the machine is controlled
between 50 and 70 volts. If using the Lincoln K930-
1 TIG Module, set the Hot start to 10 for maximum
OCV.
•
The Arc Control is not used in the TIG mode.
CV-WIRE: The CV-WIRE mode features continuous
control from 10 to 40 volts. This mode was intended
for most GMAW, FCAW, and MCAW applications.
•
The Hot Start control is not used in the CV-WIRE
mode.
•
The Arc Control regulates pinch effect. At the mini-
mum setting (-10), minimizes pinch and results in a
soft arc. Low pinch settings are preferable for weld-
ing with gas mixes containing mostly inert gases. At
the maximum setting (+10), maximizes pinch effect
and results in a crisp arc. High pinch settings are
preferable for welding FCAW and GMAW with CO
2
.
CV-INNERSHIELD: The CV-INNERSHIELD mode
features continuous control from 10 to 45 volts. This
mode was designed for self-shielded flux cored wires
that require tight voltage control.
•
The Hot Start control is not used in the CV-INNER-
SHIELD mode.
IINVERTEC V450-PRO (CE)
•
The Arc Control regulates pinch effect. At the mini-
mum setting (-10), minimizes pinch and results in a
soft arc. At the maximum setting (+10), maximizes
pinch effect and results in a crisp arc. Most self-
shielded wires work well at an Arc Control setting of 5.