F - MAINTENANCE
8695 4496 / B
F-30
FLEXCUT 125 CE INSTALLATION
2.3
Explanation of alarms : plasma
Flexcut 125 CE
The alarms indicating
Flexcut 125
plasma process faults are indicated on the UI.
Alarm
Probable causes
Possible remedies
1071: No operating feedback from the
filter
The filter has been activated, but
the feedback indicating that it is
working properly is not correct.
Check that the extraction system
is being powered.
01254 = Plasma 1
electrode/workpiece voltage fault
The voltage between the
electrode and the workpiece has
risen too fast. Often due to an arc
break.
Put the plasma back on the plate
and restart cutting.
01255 = Plasma 2
electrode/workpiece voltage fault
The voltage between the
electrode and the workpiece has
risen too fast. Often due to an arc
break.
Put the plasma back on the plate
and restart cutting.
01262 = Upper limit switch fault and
plasma TH being regulated
One of the upper limit switches of
a torch that is being regulated is
active.
Mechanically raise the tool holder
so that it can cut higher
01263 = Plasma TH in low position
fault
One of the lower limit switches of
the torch is active
Correct the fault, raise the tool
holder and clear the alarm
01264 = Cutting start fault or power
source 1 off
A pilot arc request has been
made, but the arc has not been
transferred on sheet
Switch on the power source or
change the consumables or
decrease the transfer height.
01265 = Cutting start fault or power
source 2 off
A pilot arc request has been
made, but the arc has not been
transferred on sheet
Switch on the power source or
change the consumables or
decrease the transfer height.
01268 = Voltage fault plasma 1
Slag inside the external cap
Check the spare parts, or select
a bigger amperage (aluminum),
or disconnect the detection cable
to make a mechanical detection
01269 = Voltage fault plasma 2
Slag inside the external cap
Check the spare parts, or select
a bigger amperage (aluminum),
or disconnect the detection cable
to make a mechanical detection
01272 = Arc interrupted plasma 1
The arc has disappeared during
cutting
Reposition the program on the
sheet or restart program.
01273 = Arc interrupted plasma 2
The arc has disappeared during
cutting
Reposition the program on the
sheet or restart program.
Содержание FLEXCUT 125 CE
Страница 16: ...C DESCRIPTION 8695 4496 B C 12 FLEXCUT 125 CE INSTALLATION...
Страница 27: ...8695 4496 B D ASSEMBLY AND INSTALLATION FLEXCUT 125 CE INSTALLATION D 23...
Страница 29: ...8695 4496 B E OPERATOR MANUAL FLEXCUT 125 CE INSTALLATION E 25 4 CYCLES...
Страница 30: ...E OPERATOR MANUAL 8695 4496 B E 26 FLEXCUT 125 CE INSTALLATION...
Страница 38: ...F MAINTENANCE 8695 4496 B F 34 FLEXCUT 125 CE INSTALLATION 6 1 MAIN PARTS...
Страница 43: ...8695 4496 B F MAINTENANCE FLEXCUT 125 CE INSTALLATION F 39...