B-7
OPERATION
FLEX FEED™ 74 HT
GOUGING KIT
ELECTRIC SHOCK can kill.
• If the wire feeder is turned ON with the
process switch in the gouging position,
the welding output will turn ON.
------------------------------------------------------------------
When the gouging kit is installed, a rocker switch is used
to select between wire feeder operation and gouging
operation.
With the switch in the “weld” position, the Flex Feed™ 74
HT functions normally and the output connection for the
gouging torch is OFF.
With the switch in the “gouge” position, the power source
output and gouging connection are ON and the welding
gun is OFF.
(Do Not Switch processes while actively welding or
gouging.)
WARNING
FIGURE B.7
WIRE FEED GOUGING
ROCKER SWITCH
GOUGING STUD
(COVER NOT SHOWN)
WIRE DRIVE