A-29
INSTALLATION
FLEX FEED™ 74 HT
A
A
B
B
K
K
H
H
N
N
L
L
C
C
D
D
M
M
G
G
F
F
E
E
J
J
I
I
Function
24 VAC to feeder
Welding Output Control
+10VDC to feeder for remote control
Remote control common
0-10VDC from feeder for remote control.
Current feedback to feeder. Scaled 0-10V. 1 V =
100 amps. Referenced to pin D.
24 VAC common.
Arc Voltage feedback to feeder. Scaled 0-10V. 1
V = 10 Arc volts. Referenced to pin D.
Not used
Pin
A
B
C
D
E
F
G
N
NON-LINCOLN EQUIPMENT ADAPTER,
K2335-1,-2
The Flex Feed 74 HT may be used with non-Lincoln
Electric power sources that provide 24 VAC. The
power source must have the circular connector pin
definition shown in the table below for proper opera-
tion of the wire feeder. Be sure the power source pro-
vides 24 VAC to the wire feeder and has overcurrent
protection of no more than 15 amps. The power
source must not exceed 113VDC peak.
Operation of Lincoln wire feeders on 24 VAC may
result in lack of high wire feed speeds or reduced pull
force at high wire feed speeds. Approximate maxi-
mum WFS for Lincoln wire feeders operating with 24
VAC is:
20 tooth pinion gear 425 in/min
30 tooth pinion gear
600 in/min
Function
42 VAC feeder
Welding Output Control
Welding Output Control
Remote Voltage Control ("+" supply, from power
source)
Remote Voltage Control ("-" supply, from power
source)
Remote Voltage Control (control signal from
feeder or remote.)
Not used
42 VAC to feeder
Not used
Not used
Pin
I
D
C
E
G
F
J
K
L
N
Power Source
NON-LINCOLN POWER SOURCE
LINCOLN WIRE FEEDER
Wire Feeder