B-10
OPERATION
AIR VANTAGE
®
600X-I
HIDDEN SETUP MENU FUNCTIONS
HOT START CONTROL
Hot start can be set based off weld mode. Non-applicable weld
modes will not display hot start.
The left display will show “Hot” and “Strt” alternately at 0.5
second intervals. The right display will show a number from 0.0
to 10.0. The default value will be 5, (Figure B.8). This setting will
be stored in system memory and will be remembered between
machine power cycles.
FIGURE B.8
CV MODE SELECTION
Default CV mode will be non-synergic FCAW-SS (mode 6).
Alternate settings will be non-synergic GMAW (mode 5) and non-
synergic FCAW-GS (mode 7). The left display will show “CV” and
“type” alternately at 0.5 second intervals. The right display will
show “FC.SS”(Figure B.9), “FC.gS”(Figure B.10) or “MIG”(Figure
B.11). This setting will be stored in system memory and will be
remembered between machine power cycles. This setting will
only be visible if the process selection switch is in the CV Wire
position.
FIGURE B.9
FIGURE B.10
FIGURE B.11
REMOTE CONNECTOR SELECTION FOR STICK
AND DOWNHILL PIPE MODES.
Select between the 12-pin or 14-pin connector for remote poten-
tiometer input for STICK or DOWNHILL PIPE modes when in the
REMOTE position. The default from the factory will be the 12-pin
connector. The left display will show “Pot” and the right display
will show “12P” (Figure B.12) or “14P” (Figure B.13) based off
selection. This setting is stored in system memory and will be
remembered between machine power cycles. This selection will
only be visible for STICK and DOWNHILL PIPE modes.
FIGURE B.12
FIGURE B.13
Strt
5.0
Type
FCGS
CV
MIG
Pot
12P
Pot
14P
Type
FCSS