IS 681 ECN 4301
Page 10 of 20
Disconnect from both the gas and electrical supply before proceeding with
any of the following instructions.
Use only genuine Lincat spares.
TEMPERATURE CONTROL
Remove the control knob.
Undo the control panel retaining screws.
Remove the screws that retain the temperature control/switch assembly to the
control panel.
Disconnect the cable from the rotary switch.
Pull the temperature control from the switch to separate then undo the lock nut.
Reassemble in reverse order.
SAFETY THERMOSTAT.
Drain the fryer tank.
Undo the control panel (see above).
Undo the gland assembly and withdraw the capillary and bulb.
Remove the drain valve handle
Undo the four screws retaining the switch panel.
Undo the nut holding the limit stat to the switch plate. Disconnect the wiring.
Reassemble in reverse order.
FLAME SENSOR, IGNITER ELECTRODE AND LEADS
Remove the drain valve handle
Undo the four screws holding the switch panel and support under the drain valve.
Pull off the electrode cap and disconnect from the PCB (
if replacing the lead
) and
unscrew the electrode.
Reassemble in reverse order ensuring that the earth wire is reconnected on the
ignitor electrode and always use a new gasket.
Do not over tighten the screws.
COMPONENT REPLACEMENT