Page 16 of 80
I/O specifications:
Input/Output
Specification
Comments
Description
The actuator can be equipped with elec-
tronically controlled endstop signals out.
See connection diagram,
fig. 2, page 16
Brown
12 or 24 VDC (+/-)
12V ± 20%
24V ± 10%
Under normal conditions:
12V, max. 26A depending on load
24V, max. 13A depending on load
To extend actuator:
Connect Brown to positive
To retract actuator:
Connect Brown to negative
Blue
To extend actuator:
Connect Blue to negative
To retract actuator:
Connect Blue to positive
Red
Signal power supply (+)
12-24VDC
Current consumption:
Max. 40mA, also when the actuator
is not running
Black
Signal power supply GND (-)
Green
Endstop signal out
Output voltage min. V
IN
- 2V
Source current max. 100mA
NOT potential free
Yellow
Endstop signal in
Violet
Not to be connected
White
Not to be connected
IN
OUT
Actuator with endstop signal output