Page 62 of 80
BusLink service counter - Reason for last stop
For more information and easy set-up of BusLink, please follow this link to view the Quick Guide for
BusLink:
http://www.linak.com/techline/?id3=2356
Initialisation procedure:
To initialise the actuator(s), move each actuator into fully extended and fully retracted position.
Either initialise the actuators one at a time through BusLink, or use the Parallel manual service mode
(see page 54).
In case the initialisation does not solve the issue, please contact your local LINAK supplier
Possible cause
Action/Info
H-bridge error
Internal SMPS error
• Please contact your local LINAK supplier for further
instructions
Overcurrent
• The actuator(s) cannot continue in the same direction
• Reactivation is needed in the opposite direction
EOS error
• Please contact your local LINAK supplier
Hall error
• The actuator(s) stop. When seeing hall error, the actuator
goes into ‘position lost’, and the whole system will need
initialisation
Find more info on the initialisation procedure below
Out of range temperature for ambient
location
Out of range temperature at FET location
The above can be due to high environment
temperature or high duty cycle
• The error causes the actuator(s) to stop. After elimination
of the error (cooling down) and reactivation of the
movement, the actuator(s) will move normally
• This may not be used for stopping the actuator(s)
Overvoltage
• When detecting overvoltage, the actuator(s) stop. The
actuator(s) remain stopped until the error condition is
removed. To remove the error condition, the voltage level
must be below 38V and the Run In/Run Out signals must be
removed before the next movement
Undervoltage
• When detecting undervoltage, the actuator(s) stop. The
actuator(s) remain stopped until the error condition is
removed. To remove the error condition, the voltage level
must be above 8V and the Run In/Run Out signals must be
removed before the next movement
Содержание TECHLINE LA37
Страница 1: ...Page 1 of 80 LINAK COM TECHLINE Actuator LA37 User manual...
Страница 69: ...Page 69 of 80 Load and stroke curves LA37 Trunnion mounted...
Страница 78: ...Page 78 of 80...