XAC80 Profibus-DP
®
7.5 DDLM_Chk_Cfg
The Configuration function allows the Master to send configuration data to the
Slave for any check operation. The main purpose of this function is to set the
number of bytes used for the Data_Exchange as viewed from Master side.
Chk_Cfg message structure (1 byte):
bit 7
= Consistency (=”1”)
bit 6
= Word format (“0”=byte,“1”=word=4 bytes)
bit 5 and 4
= In/out data (“01”=Input, ”10”=output)
bit 3 … 0
= Length code
EXAMPLE
bit
7
6
5
4
3
2
1
0
Data
1
1
0
1
0
0
0
1
D1h
1
1
0
1
0
0
1
1
D3h
1
1
1
0
0
0
0
1
E1h
Class 1 and Class 2:
D1hex = 4 byte input
E1hex = 4 byte output
Class 2(+VEL):
D3hex = 8 byte input
E1hex = 4 byte output
7.6 DDLM_Data_Exchange
This is the normal operation status of the system. The Slave (for both Class 1 and
Class 2) can transmit the
(and the speed value -
- if Class 2+VEL is set) and receive the
Position value
when either Class 1 or Class 2 is set
(Encoder
Master)
Byte
1
2
3
4
Bit
31-24
23-16
15-8
7-0
Data
2
31
to 2
24
2
23
to 2
16
2
15
to 2
8
2
7
to 2
0
parameter.
It has a mandatory length of 32 bits and is right aligned in the data field.
This parameter contains the current position of the encoder.
If the scaling function is enabled, the output value is scaled according to the
scaling parameters (see
MAN XAC80 PB E 1.0.odt
7 - Profibus® interface
49 of 60
Содержание XAC80 PB
Страница 21: ...XAC80 Profibus DP MAN XAC80 PB E 1 0 odt 3 Certificates 21 of 60...
Страница 22: ...XAC80 Profibus DP 3 2 EU Declaration of Conformity MAN XAC80 PB E 1 0 odt 3 Certificates 22 of 60...
Страница 23: ...XAC80 Profibus DP 3 3 Safety instructions MAN XAC80 PB E 1 0 odt 3 Certificates 23 of 60...
Страница 24: ...XAC80 Profibus DP MAN XAC80 PB E 1 0 odt 3 Certificates 24 of 60...
Страница 58: ...This page intentionally left blank...
Страница 59: ...This page intentionally left blank...