XAC80 Profibus-DP
®
Class 2(+VEL)
provides all the Class 1 and the Class 2 functions and additional
velocity-related functions:
transmission of the velocity value (see the
parameter on page 50);
setting of the unit of measurement for velocity (see the
7.3 Modes of operation
Profibus-DP devices allow operation using different communication modes (see
the Figure below):
NOTE
- are transmitted in
Set_Prm
mode.
is transmitted only in
Data_Exchange
mode.
7.3.1 Types of communication
Transmission of data between the Master and the Slave is carried out using the
following types of messages:
DDLM_Set_Prm:
It is used to configure the Slave. This communication mode is active
immediately after the power is turned ON and used to send parameters
from the Master to the Slave (see the “7.4 DDLM_Set_Prm“ section on page
41).
DDLM_Chk_Cfg:
It sets the number of bytes used for data transmission in
Data_Exchange
mode (see the “7.5 DDLM_Chk_Cfg“ section on page 49).
MAN XAC80 PB E 1.0.odt
7 - Profibus® interface
40 of 60
Power-ON
Wait_Prm
Wait_Cfg
Data_Exchange
Chk_Cfg_OK
Set_Prm_OK
Set_Prm_FAIL
Chk_Cfg_FAIL
Init_OK
Содержание XAC80 PB
Страница 21: ...XAC80 Profibus DP MAN XAC80 PB E 1 0 odt 3 Certificates 21 of 60...
Страница 22: ...XAC80 Profibus DP 3 2 EU Declaration of Conformity MAN XAC80 PB E 1 0 odt 3 Certificates 22 of 60...
Страница 23: ...XAC80 Profibus DP 3 3 Safety instructions MAN XAC80 PB E 1 0 odt 3 Certificates 23 of 60...
Страница 24: ...XAC80 Profibus DP MAN XAC80 PB E 1 0 odt 3 Certificates 24 of 60...
Страница 58: ...This page intentionally left blank...
Страница 59: ...This page intentionally left blank...